Evidence map›Paper›PMID 37527792›Full record

ArticleApplied clinical informatics2023

Usability Evaluation of a Community Pharmacy Health Information Exchange Interface Prototype.

Katelyn N Hettinger, Margie E Snyder, Omolola A Adeoye-Olatunde, Alissa L Russ-Jara

Abstract read
In one paragraph

Article in Applied clinical informatics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Katelyn N HettingerDepartment of Pharmacy Practice, Purdue University College of Pharmacy West Lafayette, Indiana, United States.
Margie E SnyderDepartment of Pharmacy Practice, Purdue University College of Pharmacy West Lafayette, Indiana, United States.
Omolola A Adeoye-OlatundeDepartment of Pharmacy Practice, Purdue University College of Pharmacy West Lafayette, Indiana, United States.
Alissa L Russ-JaraDepartment of Pharmacy Practice, Purdue University College of Pharmacy, and Regenstrief Center for Healthcare Engineering, West Lafayette, Indiana, United States.

Funding

Indiana Clinical and Translational Sciences InstituteUL1TR001108 · NCATS · INDIANA UNIVERSITY INDIANAPOLIS · PI DENNE, SCOTT C., SHEKHAR, ANANTHA · 2013 to 2017
$23.3M
Indiana Clinical and Translational Sciences InstituteKL2TR001106 · NCATS · INDIANA UNIVERSITY INDIANAPOLIS · PI DENNE, SCOTT C., SHEKHAR, ANANTHA · 2013 to 2017
$3.2M
NRSA Training CoreTL1TR002531 · NCATS · INDIANA UNIVERSITY INDIANAPOLIS · PI FOTI, DANIEL JUSTIN, HURLEY, THOMAS D. · 2018 to 2022
$2.5M
Indiana Clinical and Translational Sciences InstituteTL1TR001107 · NCATS · INDIANA UNIVERSITY INDIANAPOLIS · PI DENNE, SCOTT C., SHEKHAR, ANANTHA · 2013 to 2017
$2.0M
NCATS NIH HHS KL2 TR001106NCATS NIH HHS TL1 TR001107NCATS NIH HHS TL1 TR002531NCATS NIH HHS TL1TR002531NCATS NIH HHS UL1 TR001108
6 · The paper itself

Abstract

objectiveFew community pharmacies have access to health information exchange (HIE) data. We conducted a first-of-its-kind usability evaluation of an HIE interface prototype (referred to throughout as the "HIE-Pioneer mock-up") developed with pharmacists and pharmacy technicians to aid future implementation in community pharmacies.

methodsCommunity pharmacists and pharmacy technicians were recruited to complete usability evaluations with the HIE-Pioneer mock-up. Each usability evaluation lasted up to 60 minutes. System usability scale (SUS) scores were collected from each participant following each usability evaluation session and summarized with descriptive statistics. Usability evaluation videos were reviewed for common usability attributes, such as the impact of identified usability problems, learnability, and efficiency. Time on task, task success rates, and prototype utilization were also recorded.

resultsSixteen total participants completed usability testing across three community pharmacies. The average SUS score was 69.7 (scale 0-100, where 100 is the best), with pharmacists on average reporting higher satisfaction than technicians (74.1 vs. 65.3, respectively). Altogether, we identified 23 distinct usability problems. Key problems identified included needed clarification in tool label names and accessibility of HIE links within the existing workflow. Overall, the usability of the HIE-Pioneer mock-up generally fostered pharmacy professionals' ease of learning and efficiency.

conclusionOur study identified key areas, and potential solutions, to improve the usability of the HIE-Pioneer mock-up. Overall, pharmacy professionals viewed the HIE-Pioneer mock-up positively, with good satisfaction ratings. The HIE-Pioneer mock-up provides a blueprint for future HIE implementation in community pharmacy settings, which would increase community pharmacy teams' access to HIE data nationwide. Community pharmacy access to bi-directional HIE is expected to improve communication among more health care professionals involved in patient care and equip pharmacy professionals with needed information for improved clinical decision-making.

Indexed as

Community Pharmacy ServicesHealth Information ExchangePharmaciesHumansPatient CarePharmacists

Identifiers

PMID37527792
PMCPMC10567139

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.