ArticleCureus2023
Ultrasonographic Estimation of the Gestational Age Using the Fetal Kidney Length in the Second and Third Trimesters of Pregnancy Among South Indian Antenatal Women: A Cross-Sectional Study.
Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Beyond Traditional Biometry: The Role of Fetal Kidney Length in Third Trimester Gestational Age Assessment.Cureus · 2026Article
- Article
- Neonatal Renal Ultrasound Reference Values in Romanian Term Newborns: Correlations with Anthropometric Characteristics.Children (Basel, Switzerland) · 2025Article
- Ultrasonographic Measurement of the Fetal Foot Length and the Ratio of the Fetal Femur to Foot Length to Determine the Fetal Gestational Age.Journal of pharmacy & bioallied sciences · 2025Article
- Article
- Accuracy of Transverse Cerebellar Diameter in Estimating Gestational Age in the Second and Third Trimester: A Prospective Study in Saudi Arabia.Diagnostics (Basel, Switzerland) · 2025Article
- Mean Fetal Kidney Length at the Third Trimester: An Emerging Ultrasound Parameter for Gestational Age Assessment.Cureus · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background and Objective Accurately estimating the age of the fetus is crucial to prevent morbidity and mortality for both the fetus and mother during the perinatal period. Additionally, it enables early intervention in cases of complicated pregnancies. Multiple parameters are used for the estimation of fetal gestational age (FGA) and the expected date of delivery (EDD), but no single parameter is found to be accurate and standard. This study aims to analyze the fetal kidney length (FKL) as a means to estimate gestational age and investigate the growth pattern of the fetal kidney during the early and late weeks of gestation. Furthermore, it seeks to establish correlations between FKL and gold standard parameters from the 18th week to the 38th week of gestation. Methodology This cross-sectional research was carried out after obtaining proper institutional ethical clearance. The pregnant women who came to the gynecology outpatient department (OPD) between 18 and 38 weeks were included in this study after obtaining informed consent. The fetal biometry was measured using the ultrasonographic transducer (3-5 MHz). Results The mean FKL exhibited a consistent increase throughout the entire pregnancy, ranging from 16.50 ± 2.10 to 39.20 ± 3.10 mm. The rate of increase in FKL was significant between the early weeks (18-24) of pregnancy, with insignificant growth in other weeks of gestation. The growth of the fetal kidney (length) exhibited a gradual increase from the early weeks to the late weeks of pregnancy, with a consistent growth rate of approximately 1mm per week from 18 to 35 weeks. However, in the final three weeks of pregnancy (36th, 37th, and 38th weeks), the FKL measurements were recorded as 37.90 ± 3.90, 38.90 ± 3.10, and 40.20 ± 3.10 mm, respectively. A positive correlation was noted between the FKL with all standard parameters such as biparietal diameter (BPD), femur length (FL), head circumference (HC), and abdominal circumference (AC). Conclusions This study concluded that incorporating FKL alongside standard fetal biometric parameters such as BPD, FL, HC, and AC enhanced the accuracy of calculating FGA and EDD during the early second trimester. Furthermore, it proved beneficial in diagnosing fetal anomalies during early pregnancies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.