Metal artifact reduction on musculoskeletal CT: a phantom and clinical study.
Article in European radiology experimental, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Dual-energy CT fusion imaging improves ice-ball visualization in bone during spinal cryoablation in porcine cadavers.European radiology experimental · 2026Article
- Image quality and radiation dose of cone-beam CT versus multidetector CT for upper extremity osteosynthesis.Scientific reports · 2026Article
- The potential of high-Z contrast media for vessel visualization near metal implants: a photon-counting detector CT phantom study with virtual monoenergetic images and iterative metal artifact reduction.Quantitative imaging in medicine and surgery · 2026Article
- Application of streak metal artifact reduction technique in cone-beam computed tomography guided percutaneous transthoracic needle biopsy.World journal of radiology · 2026Article
- Metal artifact reduction and contrast agent performance as a function of source spectral shape.Physics in medicine and biology · 2025Article
- Model observer task-based assessment of computed tomography metal artifact reduction using a hip arthroplasty phantom.Medical physics · 2025Article
- Assessment of metal artifacts from titanium wrist prostheses: photon-counting versus energy-integrating detector CT.European radiology experimental · 2025Article
- Fixation of Lateral Extra-articular Tenodesis With a Biointegrative Compression Staple.Arthroscopy techniques · 2025Article
- A Comparative Finite Element Analysis of Titanium, Autogenous Bone, and Polyetheretherketone (PEEK)-Based Solutions for Mandibular Reconstruction.Materials (Basel, Switzerland) · 2025Article
- Influence of helical pitch and gantry rotation time on image quality and file size in ultrahigh-resolution photon-counting detector CT.Scientific reports · 2024Article
- Assessment of material identification and quantification in the presence of metals using spectral photon counting CT.PloS one · 2024Article
- Monitoring osseointegration and degradation of Mg-alloy implants through plasma biomarkers of inflammation and bone regeneration.Journal of tissue engineeringArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundArtifacts caused by metal implants are challenging when undertaking computed tomography (CT). Dedicated algorithms have shown promising results although with limitations. Tin filtration (Sn) in combination with high tube voltage also shows promise but with limitations. There is a need to examine these limitations in more detail. The purpose of this study was to investigate the impact of different metal artefact reduction (MAR) algorithms, tin filtration, and ultra-high-resolution (UHR) scanning, alone or in different combinations in both phantom and clinical settings.
methodsAn ethically approved clinical and phantom study was conducted. A modified Catphan® phantom with titanium and stainless-steel inserts was scanned with six different MAR protocols with tube voltage ranging from 80 to 150 kVp. Other scan parameters were kept identical. The differences (∆) in mean HU and standard deviation (SD) in images, with and without metal, were measured and compared. In the clinical study, three independent readers performed visual image quality assessments on eight different protocols using retrospectively acquired images.
resultsIterative MAR had the lowest ∆HU and ∆SD in the phantom study. For images of the forearm, the soft tissue noise for Sn-based 150-kVp UHR protocol with was significantly higher (p = 0.037) than for single-energy MAR protocols. All Sn-based 150-kVp protocols were rated significantly higher (p < 0.046 than the single-energy MAR protocols in the visual assessment.
conclusionsAll Sn-based 150-kVp UHR protocols showed similar objective MAR in the phantom study, and higher objective MAR and significantly improved visual image quality than single-energy MAR. RELEVANCE STATEMENT: Images with less metal artifacts and higher visual image quality may be more clinically optimal in CT examination of musculoskeletal patients with metal implants. KEY POINTS: • Metal artifact reduction algorithms and Sn filter combined with high kVp reduce artifacts. • Metal artifact reduction algorithms introduce new artifacts in certain metals. • Sn-based protocols alone may be considered as low metal artifact protocols.