ArticleScientific reports2023
Mechanical properties of a bioabsorbable magnesium interference screw for anterior cruciate ligament reconstruction in various testing bone materials.
Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Biodegradable Magnesium-Based Implants in Sports Orthopedic Surgery: Advances in Alloy Design, Surface Engineering, and Translational Evidence.Bioengineering (Basel, Switzerland) · 2026Review
- No single best technique: trade-offs in femoral interference screw fixation for bone-patellar tendon-bone anterior cruciate ligament reconstruction.EFORT open reviews · 2026Review
- Magnesium degradation-induced variable fixation plates promote the vascularization of femoral fracture in rabbits.Journal of orthopaedic surgery and research · 2026Article
- Biomechanical analysis of biodegradable magnesium, zinc, and polylactide pins for fixation of radial head fractures.Journal of orthopaedic surgery and research · 2025Article
- A Structural Optimization Framework for Biodegradable Magnesium Interference Screws.Biomimetics (Basel, Switzerland) · 2025Article
- The Development and Biomechanical Analysis of an Allograft Interference Screw for Anterior Cruciate Ligament Reconstruction.Bioengineering (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Tears of the anterior cruciate ligament (ACL) negatively impact the stability and kinematics of the knee. Interference screws (ISs) are used for graft fixation in ACL reconstruction and provide sufficient fixation strength to withstand the patients' activities during the graft-to-bone integration process. Magnesium is a novel material used to manufacture IS given its strength and bioabsorbability. In previous studies, the selected magnesium IS design showed a better fixation performance in comparison to the conventional IS design due to its shape design and surface condition. In this study, bioabsorbable magnesium ISs were tested for their insertion (insertion torque and a number of turns to implement the IS) and fixation performance (pull-out and dynamic test). To obtain a reliable initial assessment of IS performance, ISs were implanted in 15 per cubic foot (PCF) Sawbones polyurethane foam blocks, Sawbones biomechanical tibia models with 17 PCF foam cores, and human cadaveric tibiae. Porcine tendons were used in the foam block pull-out test, and nylon ropes were used in all other test setups to prevent influences of the ligament graft material itself. In the pull-out test, the graft was subjected to tensile stress at a rate of 6 mm/min. For the dynamic test, 1000 cycles between 0 and 200 N were performed, followed by a final pull-out test. After each test, the tunnel widening pattern was observed by measuring the aspect ratio of the tunnel at the insertion site. The insertion torque lies within the normal insertion torque of the ISs as well as the average ligament tension before the insertion. In the foam block setup, the nylon rope showed a higher pull-out force than the porcine tendon. The comparison of each setup using nylon rope for both pull-out and pull-out after the dynamic test showed no significant difference between the foam block and cadaver setup. However, all tibia model setup shows unexpectedly high pull-out force due to the influence of its cortical layer. There were no statistically significant differences in tunnel widening between foam block-porcine tendon and foam block-nylon rope constructs. The pull-out resistance of magnesium ISs falls within the typical ACL tension range during daily activities. Even though the test results of the magnesium ISs are different in each bone material, the magnesium IS shows adequate fixation ability and workability during insertion without material failure.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.