Evidence map›Paper›PMID 37523236›Full record

ArticleMedical physics2023

Quantitative analysis of small coronary artery calcium detectability with an accurate simulation and validation on a clinical CT scanner.

Lauren M Severance, Jed D Pack, Francisco J Contijoch, Elliot R McVeigh

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 60% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Lauren M SeveranceDepartment of Bioengineering, UC San Diego School of Engineering, La Jolla, California, USA.
Jed D PackRadiation Systems Lab, GE Global Research, Niskayuna, New York, USA.
Francisco J ContijochDepartment of Bioengineering, UC San Diego School of Engineering, La Jolla, California, USA.
Elliot R McVeighDepartment of Bioengineering, UC San Diego School of Engineering, La Jolla, California, USA.
University of California, San Diego · USGE Global Research (United States) · US

Funding

Integrative Bioengineering of Heart, Vessels, and BloodT32HL105373 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI CHIEN, SHU, INTAGLIETTA, MARCOS · 2010 to 2019
$3.6M
True 4DCT for Quantifying LV Dyssynchrony and Function for Targeting LV Lead Location in CRTR01HL144678 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI MCVEIGH, ELLIOT R · 2019 to 2022
$3.3M
Novel methods for earlier detection of coronary artery calcium using CTF31HL151081 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI SEVERANCE, LAUREN · 2020 to 2022
$91k
NHLBI NIH HHS F31 HL151081NHLBI NIH HHS R01 HL144678NHLBI NIH HHS T32 HL105373
6 · The paper itself

Abstract

backgroundThe absence of coronary artery calcium (CAC) measured via CT is associated with very favorable prognosis, and current guidelines recommend low-density lipoprotein cholesterol (LDL-c) lowering therapy for individuals with any CAC. This motivates early detection of small granules of CAC; however, calcium scan sensitivity for detecting very low levels of calcium has not been quantified. PURPOSE: In this work, the size limit of detectability of small calcium hydroxyapatite (CaHA) granules with clinical CAC scanning was assessed using validated simulations.

methodsCT projections of digital 3D mathematical phantoms containing small CaHA granules were simulated analytically; images were reconstructed using a filter designed to reproduce the point spread function of a specific commercial scanner, and a relationship of HU number versus diameter was derived. These simulation results were validated with experimental measurements of HU versus diameter from phantoms containing small granules of CaHA on a GE Revolution CT scanner in the clinic; ground truth measurements of the CaHA granule diameters were obtained using a Zeiss Xradia 510 Versa high-resolution 3D micro-CT imaging system. Using experimental measurements on the clinical CT scanner, detectability was quantified with a detectability index (d') using a non-prewhitened matched filter. The effect of changes to reconstruction slice thickness and reconstruction kernel on granule detectability was evaluated.

resultsUnder typical clinical calcium scanning and reconstruction conditions, the minimum detectable diameter of a simulated spherical calcium granule with a clinically relevant CaHA density was 0.76 mm. The minimum detectable volume was 2.4 times smaller on images reconstructed at a slice thickness of 0.625 mm compared to 2.5 mm. The detectability index d' increased by a factor of 1.7 when images were reconstructed with 0.625 mm slices compared to 2.5 mm slices. d' did not change when images were reconstructed with the high-resolution BONE filter compared to the less sharp STANDARD resolution filter on the GE Revolution CT.

conclusionsWe have quantified detectability versus size of small calcium granules at the resolution limit of a widely available clinical CT scanner. Detectability increased significantly with reduced slice thickness and did not change with a sharper reconstruction kernel. The simulation can be used to calculate the trade-off between dose and CAC detectability.

Indexed as

CalciumTomography, X-Ray ComputedCoronary VesselsHumansImaging, Three-DimensionalPhantoms, ImagingTomography Scanners, X-Ray ComputedCalciumCAC cardiac imagingCAC cardiac imaging.computed tomographycoronary artery calcium

Identifiers

PMID37523236
PMCPMC12039861
OpenAlexW4385429845

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.