ArticlePhysical and engineering sciences in medicine2023
Dynamic intrafractional position monitoring with implanted fiducial markers for enhanced accuracy in radiotherapy of prostate cancer.
Article in Physical and engineering sciences in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 7 citations in OpenAlex.
- Accuracy of surface-guided radiotherapy-based positioning and surface tracking in breast radiotherapy using a thermo-optical camera system.Physical and engineering sciences in medicine · 2026Article
- Impact of intrafraction fiducial tracking on planning target margins during prostate stereotactic body radiotherapy using Brainlab ExacTrac Dynamic with robotic couch correction.Journal of applied clinical medical physics · 2025Article
- A hybrid IGRT workflow using SGRT and CBCT for prostate SBRT: Feasibility, efficiency, and safety.Journal of applied clinical medical physics · 2025Article
- A Randomized Trial on Accelerated Versus Standard Small-margin Radiation Schedule in Patients With Prostate Cancer Treated With Combined Brachytherapy and External Beam Radiation Therapy: Toxicity Outcomes and Patterns of Prostate Movement.Advances in radiation oncology · 2025Article
- Simulating an intra-fraction adaptive workflow to enable PTV margin reduction in MRIgART volumetric modulated arc therapy for prostate SBRT.Frontiers in oncology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 1 institution in 1 country.
Funding
Abstract
introductionRecent advances in the radiation therapy of prostate cancer have brought a shift toward moderate- and ultra-hypofractionated treatment schedules. Reducing safety margins can broaden the therapeutic window in stereotactic treatments and alleviate concerns for toxicity in high dose-per-fraction treatment schedules. Management of intrafractional motion is a necessity for stereotactic body radiation therapy (SBRT). It can be achieved by performing intrafractional image guidance and position corrections. We evaluate the suitability of such a novel prostate motion management system and its potential benefit for treatment accuracy.
methodsIntrafractional IGRT was performed for 22 patients during 149 treatment sessions using repeated orthogonal kV-XR imaging of implanted fiducial markers with the ExacTrac Dynamic (EXTD) system. Position measurements were taken four times during each arc of the applied volumetric modulated arc therapy (VMAT). Position correction was performed if translational deviation exceeded 2 mm in any direction.
resultsOf 677 single EXTD measurements, 20.6% exceeded the predefined threshold of 2 mm 3D deviation. Without intrafractional corrections, 39.4% of all individual measurements would exceed the threshold. The 3D accuracy could thus significantly be improved, reducing mean 3D shifts from 1.97 (± 1.44) mm to 1.39 (± 1.01) mm by performing intrafractional IGRT. In total, 34% of all treatment sessions required correction of intrafractional position shifts.
conclusionMonitoring of prostate motion using repeated intrafractional orthogonal kV-X-ray-based position measurements of implanted fiducial markers proved to be a reliable method to improve precision of stereotactic irradiations of the prostate. It can prevent unacceptable translation deviations in one third of all sessions.