Evidence map›Paper›PMID 37522978›Full record

ArticleJournal of clinical monitoring and computing2023

Are all ventilators for NIV performing the same? A bench analysis.

Sara Martínez-Castro, Francisco Javier Belda Nacher, Jaume Puig Bernabeu, Marina B Soro Domingo, Carlos Delgado Navarro, Héctor Ortega Pons

Open access · hybridAbstract read
In one paragraph

Article in Journal of clinical monitoring and computing, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Home mechanical ventilator device transitions: A narrative review of clinical considerations to create a transition tool.Canadian journal of respiratory therapy : CJRT = Revue canadienne de la therapie respiratoire : RCTR · 2026
    Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Sara Martínez-CastroAnesthesia and Critical Care Department, Hospital Clínico Universitario de Valencia (HCUV), Valencia, Spain.ORCID 0000-0001-6767-5422
Francisco Javier Belda NacherUniversidad de Valencia (UV), Valencia, Spain.
Jaume Puig BernabeuUniversidad de Valencia (UV), Valencia, Spain. jaume.puig@uv.es.
Marina B Soro DomingoAnesthesia Department, Hospital IMED Valencia (ES), IMED, Valencia, Spain.
Carlos Delgado NavarroAnesthesia and Critical Care Department, Consorcio Hospital General Universitario de Valencia (CHGUV), Valencia, Spain.
Héctor Ortega PonsInstituto de Investigación Sanitaria de Valencia (INCLIVA), Valencia, Spain.
Universitat de València · ESHospital Clínico Universitario de Valencia · ESHospital General Universitario De Valencia · ESINCLIVA Health Research Institute · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Global pandemic due to COVID-19 has increased the interest for ventilators´ use worldwide. New devices have been developed and older ones have undergone a renewed interest, but we lack robust evidence about performance of each ventilator to match appropriate device to a given patient and care environment. The aim of this bench study was to investigate the performance of six devices for noninvasive ventilation, and to compare them in terms of volume delivered, trigger response, pressurization capacity and synchronization in volume assisted controlled and pressure support ventilation. All ventilators were tested under thirty-six experimental conditions by using the lung model ASL5000® (IngMar Medical, Pittsburgh, PA). Two leak levels, two muscle inspiratory efforts and three mechanical patterns were combined for simulation. Trigger function was assessed by measurement of trigger-delay time. Pressurization capacity was evaluated as area under the pressure-time curve over the first 500 ms after inspiratory effort onset. Synchronization was evaluated by the asynchrony index and by incidence and type of asynchronies in each condition. All ventilators showed a good performance, even if pressurization capacity was worse than expected. Leak level did not affect their function. Differences were found during low muscle effort and obstructive pattern. In general, Philips Trilogy Evo/EV300 and Hamilton C3 showed the best results. NIV devices successfully compensate air leaks but still underperform with low muscle effort and obstructive lungs. Clinicians´ must have a clear understanding of the goals of NIV both for devices´ choice and set main parameters to achieve therapy success.

Indexed as

Noninvasive VentilationRespiration, ArtificialEquipment DesignHumansPositive-Pressure RespirationVentilators, MechanicalBench studyBreathing mechanicsComputer simulationNoninvasive ventilationRespiratory mechanicsVentilator performance

Identifiers

PMID37522978
PMCPMC10651552
OpenAlexW4385405944

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.