Evidence map›Paper›PMID 37521950›Full record

ArticleJournal of orthopaedics2023

Optimal additional support screw position for prevention of hinge fracture in biplanar closed wedge distal femoral osteotomy.

Masaru Higa, Hiroshi Nakayama, Ryo Kanto, Shintaro Onishi, Shinichi Yoshiya, Toshiya Tachibana, Tomoya Iseki

Open access · greenAbstract read
In one paragraph

Article in Journal of orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Masaru HigaDepartment of Mechanical Engineering, University of Hyogo, 2167 shosha, Himeji, Hyogo, 671-2280, Japan.
Hiroshi NakayamaDepartment of Orthopaedic Surgery, Hyogo Medical University, Mukogawa-cho, Nishinomiya, Hyogo, 653-8501, Japan.
Ryo KantoDepartment of Orthopaedic Surgery, Hyogo Medical University, Mukogawa-cho, Nishinomiya, Hyogo, 653-8501, Japan.
Shintaro OnishiDepartment of Orthopaedic Surgery, Nishinomiya Kaisei Hospital, 1-4 Ohamacho, Nishinomiya, Hyogo, 662-0957, Japan.
Shinichi YoshiyaDepartment of Orthopaedic Surgery, Nishinomiya Kaisei Hospital, 1-4 Ohamacho, Nishinomiya, Hyogo, 662-0957, Japan.
Toshiya TachibanaDepartment of Orthopaedic Surgery, Hyogo Medical University, Mukogawa-cho, Nishinomiya, Hyogo, 653-8501, Japan.
Tomoya IsekiDepartment of Orthopaedic Surgery, Hyogo Medical University, Mukogawa-cho, Nishinomiya, Hyogo, 653-8501, Japan.
Hyogo Prefectural Nishinomiya Hospital · JPUniversity of Hyogo · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The purpose of this study was to examine the biomechanical significance of supplemental fixation using a positional screw in prevention of the hinge fracture in lateral closed-wedge distal femoral osteotomy (LCW-DFO) by means of a three-dimensional finite element analysis. Methods: The three-dimensional numerical knee models with LCW-DFO were developed. To assess the mechanical efficacy of the positional screw and determine its optimal position and orientation, in total, 13 screwing methods were analyzed. In the first four methods, the screw was supported by the cortical bone only on the medial surface (mono-cortical). In the other 9 models, the screw was supported by both medial and lateral cortical bones (bi-cortical). Under 1000 N of vertical force and 5 Nm of rotational torques, the highest shear stress value around the medial hinge area was adopted as an analytical parameter. Results: In mono-cortical methods, with the cancellous bone support, all methods were able to reduce the highest stress value compared to the value without the screw, while the efficacy was rather inferior when the screw was in horizontal direction. Without the cancellous bone support, however, all methods were not able to reduce the stress value. In bi-cortical methods, with the cancellous bone support, almost all screw augmentation methods were able to reduce the stress value. When screwing from the medial to the lateral, it only gets worse when going extremely posterior. Without the cancellous bone support, all methods were able to reduce the stress value. Conclusion: The mechanical efficacy of the bi-cortical method was proven regardless of the quality of the local cancellous bone.

Indexed as

Distal femur osteotomyHinge fractureKneeOsteotomyScrew fixation

Identifiers

PMID37521950
PMCPMC10382836
OpenAlexW4384701651

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.