Evidence map›Paper›PMID 37521949›Full record

ArticleJournal of orthopaedics2023

The Watson Extraction System for removal of well-fixed femoral stems: A retrospective review of 10 cases.

Kevin Salomon, Victor Shen, Alex Sullivan, Christopher Grayson, Steven Lyons, Brian T Palumbo

Open access · greenAbstract read
In one paragraph

Article in Journal of orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Femoral stem extraction devices.Archives of orthopaedic and trauma surgery · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Kevin SalomonUniversity of South Florida Morsani College of Medicine, 560 Channelside Dr, Tampa, FL, 33602, USA.
Victor ShenUniversity of South Florida Morsani College of Medicine, 560 Channelside Dr, Tampa, FL, 33602, USA.
Alex SullivanUniversity of South Florida Morsani College of Medicine, 560 Channelside Dr, Tampa, FL, 33602, USA.
Christopher GraysonUniversity of South Florida Morsani College of Medicine, 560 Channelside Dr, Tampa, FL, 33602, USA.
Steven LyonsUniversity of South Florida Morsani College of Medicine, 560 Channelside Dr, Tampa, FL, 33602, USA.
Brian T PalumboUniversity of South Florida Morsani College of Medicine, 560 Channelside Dr, Tampa, FL, 33602, USA.
University of South Florida · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Revision of well-fixed cementless femoral stems is a challenging and time-consuming aspect of revision hip arthroplasty. The Watson Extraction System (WES) is a novel, size-specific 3-D fabricated instrument that mimics the outer geometry of the implanted femoral stem. The device acts to cut circumferentially around the stem as it is impacted into place, effectively disrupting the bone-implant interface. Methods: This is a retrospective review assessing the experience of 3 fellowship-trained adult reconstruction surgeons who used the WES to extract 10 well-fixed femoral stems during rTHA between 11/7/2020 and 11/7/2022. Outcomes and measures included: ability to remove the stem without a femoral osteotomy, femoral stem extraction time, incidence of femoral fracture, stem type used for reconstruction, blood loss, total surgical time, post-operative complications. Results: No femoral osteotomies were required. The mean time for stem extraction was 7 min (range, 2-13), and there were 2 (20%) intra-operative femoral fractures. The stem type utilized for reconstruction included: 4 (40%) modular, tapered style stems, 3 (30%) antibiotic spacers, 2 (20%) primary style stems, and 1 (10%) ream and broach proximally porous stem. The mean blood loss was 425 ml (range, 200-800), total surgical time was 160 min (range, 107-232), and duration of follow-up was 7 months (range, 2-22 months). Conclusion: The WES may mitigate the need for femoral osteotomy, reduce femoral stem extraction and overall intraoperative time, and decrease blood loss in rTHA. Further, reduced bone loss with use of this device may permit final reconstruction with a primary style stem.

Indexed as

Blood lossExtended trochanteric osteotomy (ETO)Femoral stem extractionOperative timeRevision total hip arthroplasty (rTHA)

Identifiers

PMID37521949
PMCPMC10374600
OpenAlexW4384564524

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.