ArticleFrontiers in medicine2023
Effect of long-term rotation on astigmatism following EVO-toric intraocular collamer lens implantation.
Article in Frontiers in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Rotational stability and visual outcomes of toric implantable collamer lenses in eyes with horizontal and non-horizontal implanting orientation: an observational study.International ophthalmology · 2026Observational
- Evaluating Rotational Stability of the Visian V4b TICL in Patients with High Myopic Astigmatism.Ophthalmology and therapy · 2026Article
- Implantable collamer lens combined with femtosecond laser-assisted arcuate keratotomy and toric implantable collamer lens for high myopia with moderate-to-low astigmatism corrections: a comparative study.BMC ophthalmology · 2026Article
- Vector outcomes after SMILE pro with the VISUMAX 800 for high versus moderate-to-low astigmatism: a contralateral eye comparison.Frontiers in medicine · 2026Article
- Toric versus Standard Implantable Collamer Lens Implantation for Low Myopic Astigmatism: A 12-Month Retrospective Study.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
- Artificial Intelligence Prediction of Postoperative Rotation Stability After Toric Implantable Collamer Lens Implantation.Translational vision science & technology · 2025Article
- Article
- Comparison of monovision surgery using ICL V4c or femtosecond laser LASIK for myopia correction in the presbyopia age patients.Scientific reports · 2025Article
- Posterior chamber phakic intraocular lens adjustment-causes and complications: a retrospective cohort study.International journal of ophthalmology · 2025Article
- Long-Term Evaluation of Central and Peripheral Lens Densities Post Implantation of Implantable Collamer Lens V4c.Clinical ophthalmology (Auckland, N.Z.) · 2025Article
- Clinical Outcomes and Astigmatism Vector Analysis of High Toricity Visian ICL.Romanian journal of ophthalmologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective: To evaluate the effect of long-term rotation on astigmatism following Evolution-toric intraocular collamer lens (EVO-TICL) implantation. Methods: Forty eyes of 22 patients were enrolled in this prospective study. Visual acuity, refractive parameters, and axial position of the EVO-TICL by OPD-Scan III aberrometer were measured preoperatively, 1 month and 3 years postoperatively. Results: Last visit, the safety index was 1.32 ± 0.15 and the efficacy index was 1.01 ± 0.23. The best-fitting curve of the attempted versus achieved correction was y = 0.9751x + 0.001. The mean spherical equivalent (SE) decreased from -8.94 ± 2.72D preoperatively to 0.06 ± 0.24D and - 0.36 ± 0.46D 1 month and 3 years postoperatively, respectively. The mean target and surgical induced astigmatism were 1.55 ± 0.61D and 1.67 ± 0.94D 3 years postoperatively. The average expected axis of the TICL was-1.15 ± 9.07 (-21-19°). One month and 3 years postoperatively, the average actual axis was -0.70 ± 9.86 (-20-20°) and - 0.35 ± 11.72 (-25-30°), respectively. The absolute rotation of the TICL was 3.70 ± 4.42 (0-22°) and 6.00 ± 6.70 (0-32°) 1 month and 3 years postoperatively, respectively ( Conclusion: EVO-TICL implantation is safe and effective, with good predictability and stability. OPD-Scan is a fast device to detect the axial position of the TICL without mydriasis, and the axial position is relatively stable in the long term postoperatively. A slight rotation of low-astigmatic TICL may not cause postoperative astigmatism, whereas rotation of the high-astigmatic TICL may cause it.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.