ArticleHeliyon2023

Study on the calibration of full polarization imager.

Tianquan Liang, Qingxin Tang, Quanzhou Yu

Abstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Tianquan LiangSchool of Geography and Environment, Liaocheng University, Liaocheng 252059, PR China.
Qingxin TangSchool of Geography and Environment, Liaocheng University, Liaocheng 252059, PR China.
Quanzhou YuSchool of Geography and Environment, Liaocheng University, Liaocheng 252059, PR China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Polarization is one of the fundamental properties of light, which has a wide range of applications and is developing rapidly. To meet the needs of polarization detection, different types of polarization instruments came into being. The precision of the polarization detection instruments is vital to the result analysis. In this paper, a full polarization imager is designed, and the radiometric calibration and polarization calibration of this instrument are studied. In radiometric calibration, the different numbers lights are set to verify the light intensity response of the imager. The mathematical model was constructed for numerical fitting, and the correlation between the fitted values and the measured values in the 490 nm, 550 nm, and 670 nm bands was above 0.99. Fixed the radiance of the integrating sphere, and adjusted exposure times. The correlation of the three bands is above 0.99, which verifies that the radiative stability of the imager is good. The polarimetric calibration system adopts the adjustable degree of polarization reference light source (APOL). The theoretical and measured values of the degree of polarization of reference light sources in three different bands are analyzed. The results show that the measurement accuracy of the 490 nm band is less than 2%. The precision of polarization measurement in the 550 nm band is less than 1.5%, and the precision of polarization calibration in the 670 nm band is less than 1%. The imager is verified to have high polarization calibration accuracy and meets the requirements of high-precision polarization detection.

Indexed as

Full Stokes vectorsPolarizationPolarization calibrationRadiometric calibration