ArticleCase studies in chemical and environmental engineering2022
Wind of change: Better air for microbial environmental control.
Article in Case studies in chemical and environmental engineering, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 0 citations in OpenAlex.
- Evaluation of disinfection efficiency of new high oxygen membrane air disinfecting machine in hospital ward environment.Scientific reports · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: The COVID19 epidemic highlighted the importance of air in the transmission of pathogens. Air disinfection is one of the key points to reduce the risk of transmission both in the health sector and in public, civil and industrial environments. All bacteria and viruses tested to date can be inactivated by UV-C rays. Laboratory tested UV-C systems are increasingly popular and proposed as effective technologies for air purification; few studies have evaluated their performance in populated indoor environments. The aim of this investigation was to evaluate the effectiveness of a UV-C disinfection system for air in a real working context. Methods: This experimental study was conducted between December 2020 and February 2021 in an office of the Department of Molecular and Developmental Medicine of the University of Siena, Italy. A pre-final version air purifier (Cleaning Air T12), capable of treating 210 m Results: Preliminary tests showed a significant 62.5% reduction in Colony-Forming Units (CFUs) with 36 °C incubation. Reductions in the particulate component were also observed. In the main test, comparison of CFU data, between the device-on phase (90 min) and the subsequent device-off phase (60 min), showed statistically significant increase (p = 0.001) of environmental contamination passing from a mean of 86.6 (65.8-107.4) to 171.1 (143.9-198.3) CFU/m Conclusions: The system, which mainly uses UV-C lamps for disinfection, was able to significantly reduce environmental and human contamination in real time. Experimental tests have shown that as soon as the device is switched off, after at least half an hour of operation, the healthiness of the air decreases drastically within 10 minutes, bringing the airborne microbial contamination (induced by the presence of operators in the environment) to levels even higher than 150% of the last value with the device on. Re-engineering strategies for system improvement were also discussed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.