Evidence map›Paper›PMID 37520923›Full record

ArticleCase studies in chemical and environmental engineering2022

Application of virtual product design to the development of HVAC solution for Incheon International Airport Modular COVID-19 testing center.

Sun Jong Noh, Mansu Park, Sim Won Chin, Changyoung Choi, Man Yeong Ha

Open access · goldAbstract readCase Reports
In one paragraph

Article in Case studies in chemical and environmental engineering, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.3field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Sun Jong NohAir Solution R&D Laboratory, LG Electronics, Changwon, 51554, Republic of Korea.
Mansu ParkH&A R&D Center, LG Electronics, Changwon, 51533, Republic of Korea.
Sim Won ChinAir Solution R&D Laboratory, LG Electronics, Changwon, 51554, Republic of Korea.
Changyoung ChoiAir Solution R&D Laboratory, LG Electronics, Changwon, 51554, Republic of Korea.
Man Yeong HaSchool of Mechanical Engineering, Pusan National University, Busan, 46241, Republic of Korea.
LG (United States) · USPusan National University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Owing to the spread of COVID-19, the need for an inspection center that can quickly determine whether travelers using the airport are infected has emerged. For rapid determination, not only polymerase chain reaction tests but also antigen-antibody tests and on-site analysis systems are required. However, because it is time- and cost-intensive to construct a building that meets the standards for negative pressure facilities, modular negative pressure facilities are being installed as alternatives. Existing negative pressure facilities have problems such as increased energy consumption due to outdoor air load and condensation due to differences in indoor and outdoor temperatures and humidities caused by excessive external air inflow to achieve the target negative pressure and air change rate (ACH). In addition, owing to the installation of additional devices, additional construction is required to use them for other purposes in the future. To solve these problems, in this study, energy recovery ventilation (ERV) was employed to develop a heating, ventilation and air conditioning (HVAC) solution for the Incheon International Airport COVID-19 Testing Center. To shorten the development period, virtual product design (VPD) using computational fluid dynamics analysis-based design of experiments was performed. Owing to the application of VPD, the Incheon International Airport Modular COVID-19 Testing Center was completed in 2 weeks. The target pressure was measured in all spaces by applying the optimal conditions derived through VPD. In addition, owing to the application of ERV, the ACH of an airborne infectious isolation room exceeded the value suggested by international organizations.

Indexed as

Computational fluid dynamics (CFD)COVID-19 testing centerEnergy recovery ventilation (ERV)HVAC solutionModular negative pressure roomVirtual product design (VPD)

Identifiers

PMID37520923
PMCPMC9482795
OpenAlexW4296242477

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked