Correcting statistical CT number biases without access to raw detector counts: Applications to high spatial resolution photon counting CT imaging.

Dalton Griner, Nikou Lei, Guang-Hong Chen, Ke Li

Open access · bronzeAbstract read
In one paragraph

Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Dalton GrinerDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
Nikou LeiDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
Guang-Hong ChenDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
Ke LiDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
University of Wisconsin–Madison · US

Funding

Next Generation Cone Beam CT with Improved Contrast Resolution and Added Spectral Imaging FunctionalityR01EB034011 · NIBIB · UNIVERSITY OF WISCONSIN-MADISON · PI Guang-Hong Chen · 2023 to 2026
$2.3M
NIBIB NIH HHS R01 EB034011NIBIB NIH HHS R01EB034011
6 · The paper itself

Abstract

backgroundDue to the nonlinear nature of the logarithmic operation and the stochastic nature of photon counts (N), sinogram data of photon counting detector CT (PCD-CT) are intrinsically biased, which leads to statistical CT number biases. When raw counts are available, nearly unbiased statistical estimators for projection data were developed recently to address the CT number bias issue. However, for most clinical PCD-CT systems, users' access to raw detector counts is limited. Therefore, it remains a challenge for end users to address the CT number bias issue in clinical applications. PURPOSE: To develop methods to correct statistical biases in PCD-CT without requiring access to raw PCD counts.

methods(1) The sample variance of air-only post-log sinograms was used to estimate air-only detector counts,

resultsExperimental results demonstrated that both sinogram domain- and image domain-based bias correction methods enabled reduced-dose PCD-CT images to match the CT numbers of reference-standard images within [-5, 5] HU. In contrast, uncorrected reduced-dose PCD-CT images demonstrated biases ranging from -25 to 55 HU, depending on the material. No increase in image noise or spatial resolution degradation was observed using the proposed methods.

conclusionsCT number bias issues can be effectively addressed using the proposed sinogram or image domain method in PCD-CT, allowing PCD-CT acquired at different radiation dose levels to have consistent CT numbers desired for quantitative imaging.

Indexed as

CT number accuracyphoton counting CTstatistical bias

Identifiers

PMID37517080
PMCPMC10592226
OpenAlexW4385392707

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.