Novel Multi-Parametric Sensor System for Comprehensive Multi-Wavelength Photoplethysmography Characterization.

Joan Lambert Cause, Ángel Solé Morillo, Bruno da Silva, Juan C García-Naranjo, Johan Stiens

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Joan Lambert CauseDepartment of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium.ORCID 0000-0002-6921-7123
Ángel Solé MorilloDepartment of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium.ORCID 0000-0001-6216-9707
Bruno da SilvaDepartment of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium.ORCID 0000-0002-4877-9688
Juan C García-NaranjoCentre of Medical Biophysics, Universidad de Oriente, Santiago de Cuba 90500, Cuba.ORCID 0000-0003-1649-3383
Johan StiensDepartment of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium.ORCID 0000-0001-5049-7885
Vrije Universiteit Brussel · BEUniversidad de Oriente · CU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Photoplethysmography (PPG) is widely used to assess cardiovascular health. However, its usage and standardization are limited by the impact of variable contact force and temperature, which influence the accuracy and reliability of the measurements. Although some studies have evaluated the impact of these phenomena on signal amplitude, there is still a lack of knowledge about how these perturbations can distort the signal morphology, especially for multi-wavelength PPG (MW-PPG) measurements. This work presents a modular multi-parametric sensor system that integrates continuous and real-time acquisition of MW-PPG, contact force, and temperature signals. The implemented design solution allows for a comprehensive characterization of the effects of the variations in these phenomena on the contour of the MW-PPG signal. Furthermore, a dynamic DC cancellation circuitry was implemented to improve measurement resolution and obtain high-quality raw multi-parametric data. The accuracy of the MW-PPG signal acquisition was assessed using a synthesized reference PPG optical signal. The performance of the contact force and temperature sensors was evaluated as well. To determine the overall quality of the multi-parametric measurement, an in vivo measurement on the index finger of a volunteer was performed. The results indicate a high precision and accuracy in the measurements, wherein the capacity of the system to obtain high-resolution and low-distortion MW-PPG signals is highlighted. These findings will contribute to developing new signal-processing approaches, advancing the accuracy and robustness of PPG-based systems, and bridging existing gaps in the literature.

Indexed as

PhotoplethysmographySignal Processing, Computer-AssistedFingersHeart RateHumansReproducibility of ResultsVolunteerscontact forcemulti-wavelengthMW-PPGphotoplethysmographyPSoCtemperature

Identifiers

PMID37514922
PMCPMC10384342
OpenAlexW4385227051

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.