Evidence map›Paper›PMID 37514884›Full record

ArticleSensors (Basel, Switzerland)2023

Comparison of Microwave Hyperthermia Applicator Designs with Fora Dipole and Connected Array.

Gulsah Yildiz, Iman Farhat, Lourdes Farrugia, Julian Bonello, Kristian Zarb-Adami, Charles V Sammut, Tuba Yilmaz, Ibrahim Akduman

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.4field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 3 countries.

Gulsah YildizDepartment of Electronics and Communication Engineering, Istanbul Technical University, 34469 Istanbul, Turkey.ORCID 0000-0002-2082-0458
Iman FarhatDepartment of Physics, University of Malta, MSD 2080 Msida, Malta.ORCID 0000-0001-8401-997X
Lourdes FarrugiaDepartment of Physics, University of Malta, MSD 2080 Msida, Malta.ORCID 0000-0002-1816-0657
Julian BonelloDepartment of Physics, University of Malta, MSD 2080 Msida, Malta.ORCID 0000-0002-1298-7645
Kristian Zarb-AdamiDepartment of Physics, University of Malta, MSD 2080 Msida, Malta.
Charles V SammutDepartment of Physics, University of Malta, MSD 2080 Msida, Malta.ORCID 0000-0002-8138-3052
Tuba YilmazDepartment of Electronics and Communication Engineering, Istanbul Technical University, 34469 Istanbul, Turkey.ORCID 0000-0003-3052-2945
Ibrahim AkdumanDepartment of Electronics and Communication Engineering, Istanbul Technical University, 34469 Istanbul, Turkey.ORCID 0000-0002-5769-6032
University of Malta · MTMedical Technologies (Czechia) · CZIstanbul Technical University · TR

Funding

European Cooperation in Science and Technology CA17115Scientific and Technological Research Council of Turkey 118S074
6 · The paper itself

Abstract

In microwave hyperthermia tumor therapy, electromagnetic waves focus energy on the tumor to elevate the temperature above its normal levels with minimal injury to the surrounding healthy tissue. Microwave hyperthermia applicator design is important for the effectiveness of the therapy and the feasibility of real-time application. In this study, the potential of using fractal octagonal ring antenna elements as a dipole antenna array and as a connected array at 2.45 GHz for breast tumor hyperthermia application was investigated. Microwave hyperthermia treatment models consisting of different fractal octagonal ring antenna array designs and a breast phantom are simulated in COMSOL Multiphysics to obtain the field distributions. The antenna excitation phases and magnitudes are optimized using the global particle swarm algorithm to selectively increase the specific absorption rate at the target region while minimizing hot spots in other regions within the breast. Specific absorption rate distributions, obtained inside the phantom, are analyzed for each proposed microwave hyperthermia applicator design. The dipole fractal octagonal ring antenna arrays are comparatively assessed for three different designs: circular, linear, and Cross-array. The 16-antenna dipole array performance was superior for all three 1-layer applicator designs, and no distinct difference was found between 16-antenna circular, linear, or cross arrays. Two-layer dipole arrays have better performance in the deep-tissue targets than one-layer arrays. The performance of the connected array with a higher number of layers exceeds the performance of the dipole arrays in the superficial regions, while they are comparable for deep regions of the breast. The 1-layer 12-antenna circular FORA dipole array feasibility as a microwave hyperthermia applicator was experimentally shown.

Indexed as

cancer therapeuticsconnected arraydipole antennafractal octagonal ring arraymicrowave hyperthermiaparticle swarm optimization

Identifiers

PMID37514884
PMCPMC10383607
OpenAlexW4385201668

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.