Evidence map›Paper›PMID 37514841›Full record

ArticleSensors (Basel, Switzerland)2023

A Transformer-Based Neural Network for Gait Prediction in Lower Limb Exoskeleton Robots Using Plantar Force.

Jiale Ren, Aihui Wang, Hengyi Li, Xuebin Yue, Lin Meng

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jiale RenSchool of Electronic and Information, Zhongyuan University of Technology, Zhengzhou 451191, China.ORCID 0000-0002-8392-5775
Aihui WangSchool of Electronic and Information, Zhongyuan University of Technology, Zhengzhou 451191, China.ORCID 0000-0002-7531-6240
Hengyi LiResearch Organization of Science and Technology, Ritsumeikan University, Kusatsu 525-8577, Japan.ORCID 0000-0003-4112-7297
Xuebin YueResearch Organization of Science and Technology, Ritsumeikan University, Kusatsu 525-8577, Japan.ORCID 0000-0002-4356-9243
Lin MengCollege of Science and Engineering, Ritsumeikan University, Kusatsu 525-8577, Japan.ORCID 0000-0003-4351-6923

Funding

National Natural Science Foundation of China 62073297
6 · The paper itself

Abstract

Lower limb exoskeleton robots have shown significant research value due to their capabilities of providing assistance to wearers and improving physical motion functions. As a type of robotic technology, wearable robots are directly in contact with the wearer's limbs during operation, necessitating a high level of human-robot collaboration to ensure safety and efficacy. Furthermore, gait prediction for the wearer, which helps to compensate for sensor delays and provide references for controller design, is crucial for improving the the human-robot collaboration capability. For gait prediction, the plantar force intrinsically reflects crucial gait patterns regardless of individual differences. To be exact, the plantar force encompasses a doubled three-axis force, which varies over time concerning the two feet, which also reflects the gait patterns indistinctly. In this paper, we developed a transformer-based neural network (TFSformer) comprising convolution and variational mode decomposition (VMD) to predict bilateral hip and knee joint angles utilizing the plantar pressure. Given the distinct information contained in the temporal and the force-space dimensions of plantar pressure, the encoder uses 1D convolution to obtain the integrated features in the two dimensions. As for the decoder, it utilizes a multi-channel attention mechanism to simultaneously focus on both dimensions and a deep multi-channel attention structure to reduce the computational and memory consumption. Furthermore, VMD is applied to networks to better distinguish the trends and changes in data. The model is trained and tested on a self-constructed dataset that consists of data from 35 volunteers. The experimental results show that FTSformer reduces the mean absolute error (MAE) up to 10.83%, 15.04% and 8.05% and the mean squared error (MSE) by 20.40%, 29.90% and 12.60% compared to the CNN model, the transformer model and the CNN transformer model, respectively.

Indexed as

Exoskeleton DeviceRoboticsGaitHumansLower ExtremityNeural Networks, Computerconvolutional neural networkgait predictionplantar pressuretransformer

Identifiers

PMID37514841
PMCPMC10384092

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.