Evidence map›Paper›PMID 37514810›Full record

ArticleSensors (Basel, Switzerland)2023

Remote Estimation of Blood Pressure Using Millimeter-Wave Frequency-Modulated Continuous-Wave Radar.

Lovedeep Singh, Sungjin You, Byung Jang Jeong, Chiwan Koo, Youngwook Kim

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Lovedeep SinghDepartment of Electrical and Computer Engineering, California State University, Fresno, CA 93740, USA.
Sungjin YouElectronics and Telecommunications Research Institute, Daejeon 34129, Republic of Korea.ORCID 0000-0003-2089-6951
Byung Jang JeongElectronics and Telecommunications Research Institute, Daejeon 34129, Republic of Korea.
Chiwan KooDepartment of Electronic Engineering, Hanbat National University, Daejeon 34158, Republic of Korea.ORCID 0000-0003-2880-1670
Youngwook KimDepartment of Electronic Engineering, Sogang University, Seoul 04107, Republic of Korea.ORCID 0000-0002-4067-6254

Funding

Electronics and Telecommunications Research Institute 22ZH1100National Research Foundation (NRF) BK21 FOUR
6 · The paper itself

Abstract

This paper proposes to remotely estimate a human subject's blood pressure using a millimeter-wave radar system. High blood pressure is a critical health threat that can lead to diseases including heart attacks, strokes, kidney disease, and vision loss. The commonest method of measuring blood pressure is based on a cuff that is contact-based, non-continuous, and cumbersome to wear. Continuous remote monitoring of blood pressure can facilitate early detection and treatment of heart disease. This paper investigates the possibility of using millimeter-wave frequency-modulated continuous-wave radar to measure the heart blood pressure by means of pulse wave velocity (PWV). PWV is known to be highly correlated with blood pressure, which can be measured by pulse transit time. We measured PWV using a two-millimeter wave radar focused on the subject's chest and wrist. The measured time delay provided the PWV given the length from the chest to the wrist. In addition, we analyzed the measured radar signal from the wrist because the shape of the pulse wave purveyed information on blood pressure. We investigated the area under the curve (AUC) as a feature and found that AUC is strongly correlated with blood pressure. In the experiment, five human subjects were measured 50 times each after performing different activities intended to influence blood pressure. We used artificial neural networks to estimate systolic blood pressure (SBP) and diastolic blood pressure (SBP) with both PWV and AUC as inputs. The resulting root mean square errors of estimated blood pressure were 3.33 mmHg for SBP and 3.14 mmHg for DBP.

Indexed as

Pulse Wave AnalysisRadarBlood PressureBlood Pressure DeterminationHumansVital Signsblood pressureFMCW radarpulse pressurepulse transit timepulse wave velocity

Identifiers

PMID37514810
PMCPMC10383350

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.