Evidence map›Paper›PMID 37514793›Full record

ArticleSensors (Basel, Switzerland)2023

Approach for Non-Intrusive Detection of the Fit of Orthopaedic Devices Based on Vibrational Data.

Constanze Neupetsch, Eric Hensel, Andreas Heinke, Tom Stapf, Nico Stecher, Hagen Malberg, Christoph-Eckhard Heyde, Welf-Guntram Drossel

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 53% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Constanze NeupetschFraunhofer Institute for Machine Tools and Forming Technology, 09126 Chemnitz, Germany.ORCID 0000-0003-4950-8721
Eric HenselFraunhofer Institute for Machine Tools and Forming Technology, 09126 Chemnitz, Germany.
Andreas HeinkeInstitute of Biomedical Engineering, Dresden University of Technology, 01307 Dresden, Germany.
Tom StapfFraunhofer Institute for Machine Tools and Forming Technology, 09126 Chemnitz, Germany.
Nico StecherInstitute of Biomedical Engineering, Dresden University of Technology, 01307 Dresden, Germany.
Hagen MalbergInstitute of Biomedical Engineering, Dresden University of Technology, 01307 Dresden, Germany.
Christoph-Eckhard HeydeDepartment of Orthopaedic, Trauma and Plastic Surgery, University of Leipzig Medical Center, 04103 Leipzig, Germany.ORCID 0000-0002-0375-0232
Welf-Guntram DrosselFraunhofer Institute for Machine Tools and Forming Technology, 09126 Chemnitz, Germany.ORCID 0000-0002-8504-4584
Technische Universität Dresden · DEChemnitz University of Technology · DEFraunhofer Institute for Machine Tools and Forming Technology · DE

Funding

Saxon State Ministry for Science and the Arts no
6 · The paper itself

Abstract

The soft tissues of residual limb amputees are subject to large volume fluctuations over the course of a day. Volume fluctuations in residual limbs can lead to local pressure marks, causing discomfort, pain and rejection of prostheses. Existing methods for measuring interface stress encounter several limitations. A major problem is that the measurement instrumentation is applied in the sensitive interface between the prosthesis and residual limb. This paper presents the principle investigation of a non-intrusive technique to evaluate the fit of orthopaedic prosthesis sockets in transfemoral amputees based on experimentally obtained vibrational data. The proposed approach is based on changes in the dynamical behaviour detectable at the outer surface of prostheses; thus, the described interface is not affected. Based on the experimental investigations shown and the derived results, it can be concluded that structural dynamic measurements are a promising non-intrusive technique to evaluate the fit of orthopaedic prosthesis sockets in transfemoral amputee patients. The obtained resonance frequency changes of 2% are a good indicator of successful applicabilityas these changes can be detected without the need for complex measurement devices.

Indexed as

AmputeesArtificial LimbsOrthopedicsAmputation StumpsHumansProsthesis DesignProsthesis Implantationacoustic sensorfrequency response analysislocal pressure marklower-limb prosthesismeasurement methodresidual limbsocket fitstructural dynamicstransfemoral amputation

Identifiers

PMID37514793
PMCPMC10386735
OpenAlexW4384827296

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.