Evidence map›Paper›PMID 37514786›Full record

ArticleSensors (Basel, Switzerland)2023

Fabry-Perot Interferometer Used to Measure Very Low Static Pressure Measurements.

Sergio Calixto, Roberto Zitzumbo, Zacarías Malacara Hernandez

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Sergio CalixtoCentro de Investigaciones en Óptica, Loma del Bosque 115, Leon 37150, Mexico.ORCID 0000-0002-5636-1580
Roberto ZitzumboCentro de Innovación Aplicada en Tecnologías Competitivas, Omega 201, Col. Industrial Delta, Leon 37545, Mexico.
Zacarías Malacara HernandezCentro de Investigaciones en Óptica, Loma del Bosque 115, Leon 37150, Mexico.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper describes the use of an optical instrument, the Fabry-Perot interferometer, adapted to measure very low pressures. The interferometer consists of two high-reflectance flat mirrors placed one in front of another. In addition, a metallic chamber contains air or a gas. In one of the faces of the chamber, a flexible thin silicone membrane is attached and, over it, one of the mirrors is glued. The other mirror rests in a fixed mechanical mounting. Light crosses both mirrors and, when it leaves them, forms an interference pattern consisting of concentric circular fringes. When the pressure is increased/decreased within the chamber, a displacement of the fringes is observed due to the movement of the glued mirror. By measuring the fringe displacement and knowing the pressure, a calibration plot can be made. Minimum pressure measurements of about tens of Pascals were achieved.

Indexed as

Fabry–Perot interferometerhigh sensitivityoptical sensorphysical sensorpolydimethyl siloxanepressure sensorsensor devicesvery low pressure measurements

Identifiers

PMID37514786
PMCPMC10386033

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.