Evidence map›Paper›PMID 37514445›Full record

ArticlePolymers2023

Feasibility of 3D-Printed Locking Compression Plates with Polyether Ether Ketone (PEEK) in Tibial Comminuted Diaphyseal Fractures.

Hyung-Jin Chung, Ho-Beom Lee, Kwang-Min Park, Tae-Gon Jung, Sang-Bum Kim, Byoung-Gu Lee, Wan-Chin Kim, Jeong-Kil Lee

Open access · goldAbstract read
In one paragraph

Article in Polymers, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Hyung-Jin ChungDepartment of Orthopaedic Surgery, Chungnam National University Sejong Hospital, Chungnam National University School of Medicine, 20, Bodeum 7-ro, Sejong-si 30099, Republic of Korea.
Ho-Beom LeeSchool of Mechanical Engineering, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea.
Kwang-Min ParkMedical Device Development Center, Osong Medical Innovation Foundation 123, Osongsaengmyeong-ro, Osong-eup, Heungdeok-gu, Cheonju-si 28160, Chungbuk, Republic of Korea.
Tae-Gon JungMedical Device Development Center, Osong Medical Innovation Foundation 123, Osongsaengmyeong-ro, Osong-eup, Heungdeok-gu, Cheonju-si 28160, Chungbuk, Republic of Korea.ORCID 0000-0002-4793-9125
Sang-Bum KimDepartment of Orthopaedic Surgery, Chungnam National University Sejong Hospital, Chungnam National University School of Medicine, 20, Bodeum 7-ro, Sejong-si 30099, Republic of Korea.
Byoung-Gu LeeDepartment of Orthopaedic Surgery, Chungnam National University Sejong Hospital, Chungnam National University School of Medicine, 20, Bodeum 7-ro, Sejong-si 30099, Republic of Korea.
Wan-Chin KimDepartment of Mechanics-Material Convergence System Engineering, Hanbat National University, 125, Dongseo-daero, Yuseong-gu, Daejeon 34158, Republic of Korea.
Jeong-Kil LeeDepartment of Orthopaedic Surgery, Chungnam National University Sejong Hospital, Chungnam National University School of Medicine, 20, Bodeum 7-ro, Sejong-si 30099, Republic of Korea.ORCID 0000-0002-3403-9240
Chungnam National University · KROsong Medical Innovation Foundation · KRHanbat National University · KR

Funding

Chungnam National University Sejong Hospital Research Fund 2021
6 · The paper itself

Abstract

The applicability of a polyether ether ketone locking compression plate (PEEK LCP) fabricated using FDM (fused deposition modeling)-based 3D printing to treat actual patients was studied. Three different tests-bending, axial compression, and axial torsion-were conducted on tibial non-osteoporotic comminuted diaphyseal fracture samples fixed with the commercial titanium alloy LCP and 3D-printed PEEK LCP. Comparing the outcomes of these tests revealed that the commercial titanium alloy LCP underwent plastic deformation in the bending and axial torsion tests, though the LCP did not fail even when an external force greater than the maximum allowable load of the tibia fixture of the LCP was applied. Elastic deformation occurred in the 3D-printed PEEK LCP in the bending and axial torsion tests. However, deformation occurred even under a small external force, and its stiffness was 10% compared to commercial titanium alloy LCP. Thus, 3D-printed PEEK LCP can be applied to the fracture conditions in non-weight-bearing regions. The experimental results reveal detailed insights into the treatment of actual patients by considering the stiffness and high toughness of 3D-printed PEEK LCP.

Indexed as

3D printingaxial compression testaxial torsion testbending testpolyether ether ketone locking compression plate (PEEK LCP)tibial fracture

Identifiers

PMID37514445
PMCPMC10384545
OpenAlexW4384557682

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.