Evidence map›Paper›PMID 37512597›Full record

ArticleMicromachines2023

3D-Printed Microfluidic One-Way Valves and Pumps.

Hunter Hinnen, Matthew Viglione, Troy R Munro, Adam T Woolley, Gregory P Nordin

Abstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. In Situ Characterisation of Hydrogels via Dynamic Interface Printing.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Biomicrofluidics · 2024
    Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hunter HinnenDepartment of Electrical & Computer Engineering, Brigham Young University, Provo, UT 84602, USA.ORCID 0000-0003-2728-2303
Matthew ViglioneDepartment of Electrical & Computer Engineering, Brigham Young University, Provo, UT 84602, USA.ORCID 0000-0001-9744-0464
Troy R MunroDepartment of Mechanical Engineering, Brigham Young University, Provo, UT 84602, USA.ORCID 0000-0002-2557-4911
Adam T WoolleyDepartment of Chemistry & Biochemistry, Brigham Young University, Provo, UT 84602, USA.ORCID 0000-0002-4699-8094
Gregory P NordinDepartment of Electrical & Computer Engineering, Brigham Young University, Provo, UT 84602, USA.ORCID 0000-0001-7241-5764

Funding

High Density 3D Printed Microfluidics With Open Source Resins for Biomedical ApplicationsR15GM123405 · NIGMS · BRIGHAM YOUNG UNIVERSITY · PI NORDIN, GREGORY P. · 2017 to 2023
$1.3M
Administrative Supplement for Equipment: 6-axis Positioner to Improve 3D Print Quality and Print SizeR15GM132868 · NIGMS · BRIGHAM YOUNG UNIVERSITY · PI MUNRO, TROY · 2019 to 2023
$944k
NIGMS NIH HHS R15 GM123405NIGMS NIH HHS R15 GM132868NIH HHS 1R15GM132868-01NIH HHS R15GM123405-02
6 · The paper itself

Abstract

New microfluidic lab-on-a-chip capabilities are enabled by broadening the toolkit of devices that can be created using microfabrication processes. For example, complex geometries made possible by 3D printing can be used to approach microfluidic design and application in new or enhanced ways. In this paper, we demonstrate three distinct designs for microfluidic one-way (check) valves that can be fabricated using digital light processing stereolithography (DLP-SLA) with a poly(ethylene glycol) diacrylate (PEGDA) resin, each with an internal volume of 5-10 nL. By mapping flow rate to pressure in both the forward and reverse directions, we compare the different designs and their operating characteristics. We also demonstrate pumps for each one-way valve design comprised of two one-way valves with a membrane valve displacement chamber between them. An advantage of such pumps is that they require a single pneumatic input instead of three as for conventional 3D-printed pumps. We also characterize the achievable flow rate as a function of the pneumatic control signal period. We show that such pumps can be used to create a single-stage diffusion mixer with significantly reduced pneumatic drive complexity.

Indexed as

3D printingmicrofluidic mixermicrofluidic pumpmicrofluidicsone-way valve

Identifiers

PMID37512597
PMCPMC10384158

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.