Evidence map›Paper›PMID 37511758›Full record

ArticleJournal of personalized medicine2023

The Clinical Efficacy of Contouring Periarticular Plates on a 3D Printed Bone Model.

Seung-Yeob Sakong, Jae-Woo Cho, Beom-Soo Kim, Sung-Jun Park, Eic-Ju Lim, Jong-Keon Oh

Abstract read
In one paragraph

Article in Journal of personalized medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Evolving fracture management: the role of helical plating in orthopaedic trauma surgery - a narrative review.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025
    Review
  4. Review
  5. Article
  6. Three-dimensional printed models can reduce costs and surgical time for complex proximal humeral fractures: preoperative planning, patient satisfaction, and improved resident skills.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2024
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Seung-Yeob SakongDepartment of Orthopaedic SurgeryAjou University Hospital, Ajou University College of Medicine, Suwon 16499, Republic of Korea.
Jae-Woo ChoDepartment of Orthopedic Surgery, Korea University Guro Hospital, Seoul 08308, Republic of Korea.
Beom-Soo KimDepartment of Orthopedic Surgery, Keimyung University Dongsan Hospital, Keimyung University Medicine, Daegu 41931, Republic of Korea.
Sung-Jun ParkDepartment of Mechanical Engineering, Korea National University of Transportation, Chungbuk 27469, Republic of Korea.
Eic-Ju LimDepartment of Orthopaedic Surgery, Chungbuk National University Hospital, Chungbuk National University College of Medicine, Cheongju 28644, Republic of Korea.ORCID 0000-0001-8095-6173
Jong-Keon OhDepartment of Orthopedic Surgery, Korea University Guro Hospital, Seoul 08308, Republic of Korea.

Funding

The ministry of science and ICT (MSIT), Republic of Korea S1222-20-1001
6 · The paper itself

Abstract

We report our experience of preoperative plate contouring for periarticular fractures using three-dimensional printing (3DP) technology and describe its benefits. We enrolled 34 patients, including 11 with humerus midshaft fractures, 12 with tibia plateau fractures, 2 with pilon fractures, and 9 with acetabulum fractures. The entire process of plate contouring over the 3DP model was videotaped and retrospectively analyzed. The total time and number of trials for the intraoperative positioning of precontoured plates and any further intraoperative contouring events were prospectively recorded. The mismatch between the planned and postoperative plate positions was evaluated. The average plate contouring time was 9.2 min for humerus shaft, 13.8 min for tibia plateau fractures, 8.8 min for pilon fractures, and 11.6 min for acetabular fractures. Most precontoured plates (88%, 30/34) could sit on the planned position without mismatch. In addition, only one patient with humerus shaft fracture required additional intraoperative contouring. Preoperative patient specific periarticular plate contouring using a 3DP model is a simple and efficient method that may alleviate the surgical challenges involved in plate contouring and positioning.

Indexed as

periarticular fractureplate fixationpreoperative plate contouringthree-dimensional printing

Identifiers

PMID37511758
PMCPMC10381594

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.