ArticleJournal of clinical medicine2023

Efficacy of Catheter Ablation Using the Electroanatomical System without the Use of Fluoroscopy in Patients with Ventricular Extrasystolic Beats.

Dariusz Rodkiewicz, Edward Koźluk, Karol Momot, Karolina Rogala, Agnieszka Piątkowska, Małgorzata Buksińska-Lisik, Przemysław Kwasiborski, Artur Mamcarz

Abstract read
In one paragraph

Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Dariusz RodkiewiczDepartment of Cardiology and Internal Diseases, Regional Hospital in Miedzylesie, 04-749 Warsaw, Poland.
Edward KoźlukDepartment of Cardiology and Internal Diseases, Regional Hospital in Miedzylesie, 04-749 Warsaw, Poland.
Karol MomotDepartment of Cardiology and Internal Diseases, Regional Hospital in Miedzylesie, 04-749 Warsaw, Poland.ORCID 0000-0001-8659-2948
Karolina RogalaDepartment of Cardiology and Internal Diseases, Regional Hospital in Miedzylesie, 04-749 Warsaw, Poland.
Agnieszka PiątkowskaDepartment of Cardiology and Internal Diseases, Regional Hospital in Miedzylesie, 04-749 Warsaw, Poland.ORCID 0000-0001-8234-2773
Małgorzata Buksińska-Lisik3rd Department of Internal Medicine and Cardiology, Medical University of Warsaw, 04-749 Warsaw, Poland.ORCID 0000-0001-7738-1049
Przemysław KwasiborskiDepartment of Cardiology and Internal Diseases, Regional Hospital in Miedzylesie, 04-749 Warsaw, Poland.
Artur Mamcarz3rd Department of Internal Medicine and Cardiology, Medical University of Warsaw, 04-749 Warsaw, Poland.ORCID 0000-0002-9569-1486

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCatheter ablation (CA) has become safe and efficient for the treatment of patients with ventricular extrasystolic beats (VEBs). The three-dimensional electroanatomic mapping (EAM) system allows the elimination of fluoroscopy time during CA procedures. Non-fluoroscopy CA is a challenging procedure requiring intimate knowledge of cardiac anatomy in patients with VEBs. The study aimed to evaluate the efficacy and safety of the non-fluoroscopy CA using the EAM system in patients with VEBs.

methodsCompletely fluoroless CA of VEBs guided by EAM was performed in 86% (94 out of 109) of consecutive patients with VEBs. The remaining 15 patients underwent conventional fluoroscopy-guided CA. Demographic and clinical baseline characteristics, procedure parameters, and following complications were obtained from the medical records. Primary outcomes were the acute procedural success rate, the permanent success rate (6-month follow-up), complications, and procedure time.

resultsThere were no significant differences between groups regarding baseline characteristics. Acute procedural success was achieved in 85 patients (90%) in the non-fluoroscopy group and in 14 patients (93%) in the fluoroscopy group (ns). A long-term success rate was achieved in 82 patients (87%) in the non-fluoroscopy group and in 14 (82%) patients in the fluoroscopy group (ns). The median procedure time was 85 min in the non-fluoroscopy group and 120 min in the fluoroscopy group (

conclusionsCompletely fluoroless CA of VEBs guided by EAM is a feasible, safe, and efficient procedure.

Indexed as

catheter ablationelectroanatomic mappingfluoroscopy eliminationventricular extrasystolic beats

Identifiers

PMID37510966
PMCPMC10381465

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.