Evidence map›Paper›PMID 37510731›Full record

ArticleJournal of clinical medicine2023

Safety Issues in the Development of an Innovative Medical Parallel Robot Used in Renal Single-Incision Laparoscopic Surgery.

Doina Pisla, Nicolae Crisan, Bogdan Gherman, Iulia Andras, Paul Tucan, Corina Radu, Alexandru Pusca, Calin Vaida, Nadim Al Hajjar

Abstract read
In one paragraph

Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Doina PislaResearch Center for Industrial Robots Simulation and Testing-CESTER, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania.ORCID 0000-0001-7014-9431
Nicolae CrisanDepartment of Urology, "Iuliu Hatieganu" University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania.
Bogdan GhermanResearch Center for Industrial Robots Simulation and Testing-CESTER, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania.ORCID 0000-0002-4427-6231
Iulia AndrasDepartment of Urology, "Iuliu Hatieganu" University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania.
Paul TucanResearch Center for Industrial Robots Simulation and Testing-CESTER, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania.
Corina RaduDepartment of Internal Medicine, "Iuliu Hatieganu" University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania.
Alexandru PuscaResearch Center for Industrial Robots Simulation and Testing-CESTER, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania.ORCID 0000-0002-5804-575X
Calin VaidaResearch Center for Industrial Robots Simulation and Testing-CESTER, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania.ORCID 0000-0003-2822-9790
Nadim Al HajjarDepartment of Urology, "Iuliu Hatieganu" University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania.

Funding

a grant of the Ministry of Research, Innovation and Digitization, CNCS/CCCDI - UEFISCDI PCE171/2021 - Challenge within PNCDI III, the project POCU/380/6/13/123927-ANTREDOC, "Entrepreneurial competencies and excellence research in doctoral and postdoctoral studies programs"the European Social Fund through the Human Capital Operational, and the grant of the Ministry of Research, Innovation and Digitization, CNCS/CCCDI-UEFISCDI PN-III-P2-2.1-PED-2021-2790 694PED-Enhance, within PNCDI III
6 · The paper itself

Abstract

Robotic-assisted single-incision laparoscopic surgery (SILS) is becoming an increasingly widespread field worldwide due to the benefits it brings to both the patient and the surgeon. The goal of this study is to develop a secure robotic solution for SILS, focusing specifically on urology, by identifying and addressing various safety concerns from an early design stage. Starting with the medical tasks and protocols, the technical specifications of the robotic system as well as potential; hazards have been identified. By employing competitive engineering design methods such as Analytic Hierarchy Process (AHP), Risk assessment, and Failure Mode and Effects Analysis (FMEA), a safe design solution is proposed. A set of experiments is conducted to validate the proposed concept, and the results strongly support the development of the experimental model. The Finite Element Analysis (FEA) method is applied to validate the mechanical architecture within a set of simulations, demonstrating the compliance of the robotic system with the proposed technical specifications and its capability to safely perform SILS procedures.

Indexed as

designparallel robotrisk assessmentsafetysingle-incision laparoscopic surgery

Identifiers

PMID37510731
PMCPMC10380956

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.