Evidence map›Paper›PMID 37510697›Full record

ArticleJournal of clinical medicine2023

Objective Assessment of Syndesmosis Stability Using the Hook Test.

Jakob Hallbauer, Philipp Schenk, Lea Herrmann, Bernhard Wilhelm Ullrich, Uta Biedermann, Britt Wildemann, Gunther Olaf Hofmann, Felix Christian Kohler

Abstract read
In one paragraph

Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Trans-syndesmotic fixation in supination external rotation type 4 injuries: Are intraoperative tests reliable?Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES · 2024
    Article
  3. Article
  4. Comparison of screw fixation and dynamic fixation in the treatment of ankle fractures with syndesmotic ruptures.Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jakob HallbauerDepartment of Trauma, Hand and Reconstructive Surgery, Jena University Hospital, Friedrich Schiller University Jena, 07747 Jena, Germany.ORCID 0000-0003-1611-0370
Philipp SchenkReseaserch Executive Department, BG Klinikum Bergmannstrost, 06112 Halle, Germany.
Lea HerrmannDepartment of Trauma, Hand and Reconstructive Surgery, Jena University Hospital, Friedrich Schiller University Jena, 07747 Jena, Germany.
Bernhard Wilhelm UllrichDepartment of Trauma and Reconstructive Surgery, BG Klinikum Bergmannstrost, 06112 Halle, Germany.
Uta BiedermannInstitute of Anatomy I, Jena University Hospital, Friedrich Schiller University Jena, 07743 Jena, Germany.
Britt WildemannDepartment of Trauma, Hand and Reconstructive Surgery, Jena University Hospital, Friedrich Schiller University Jena, 07747 Jena, Germany.ORCID 0000-0002-8365-1188
Gunther Olaf HofmannDepartment of Trauma, Hand and Reconstructive Surgery, Jena University Hospital, Friedrich Schiller University Jena, 07747 Jena, Germany.
Felix Christian KohlerDepartment of Trauma, Hand and Reconstructive Surgery, Jena University Hospital, Friedrich Schiller University Jena, 07747 Jena, Germany.ORCID 0000-0002-6863-9025

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The hook test is a widely used intraoperative method for assessing syndesmosis stability. However, there are no recommendations regarding the force required to perform this test. Furthermore, the reliability of the test is unclear. Ten experienced surgeons performed hook tests on a cadaver bone model. The applied forces were recorded in a blinded manner. In addition, standardized hook tests with defined forces (50, 80, and 100 N) were performed on 10 pairs of cadaver lower legs and the syndesmosis was sequentially destabilized. Diastasis of the syndesmosis was recorded using an optical 3D camera system. A median force of 81 N (Range: 50 N-145 N) was applied. A proportion of 82% of the tests showed a force < 100 N. The data showed good intraraterreliability and poor interraterreliability. In the standardized investigation of the hook test on the cadaver bone model, both the force and the instability of the syndesmosis had a significant influence on the syndesmosis diastasis. Nevertheless, even with maximum instability of the syndesmosis, diastasis > 2 mm could only be measured in 12 of the 19 evaluable specimens. The widely used hook test shows a high variability when performed in practice. Even in a standardized manner, the hook test cannot detect a relevant syndesmosis injury.

Indexed as

biomechanicscadaverclinical testsyndesmosistrauma surgeryupper ankle joint

Identifiers

PMID37510697
PMCPMC10380604

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked