ArticleScientific reports2023
Retrospective evaluation of percutaneous 3D-navigated screw fixation for fragility fractures of the sacrum: technical notes and four-year experience.
Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 11 citations in OpenAlex.
- Percutaneous fixation of posterior pelvic ring lesions in the elderly: current evidence and recent advances.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026Review
- Successful minimal-invasive management of misplaced sacroiliac screw perforating the left external iliac vein: an interdisciplinary intervention by angiology and traumatology-a case report.Journal of medical case reports · 2026Article
- [Surgical stabilization of fragility fractures of the pelvis shows a good age-appropriate result regardless of the surgical procedure].Unfallchirurgie (Heidelberg, Germany) · 2026Article
- Finite element analysis of sacral fixation strategies for fragility fractures of the pelvis.Scientific reports · 2026Article
- Acceptable outcomes after anterior subcutaneous pelvic Internal Fixation (INFIX) for Fragility Fractures of the Pelvis (FFP) type III in elderly patients: a retrospective study.BMC geriatrics · 2026Article
- Robot-assisted closed reduction and navigated fixation for pelvic ring injuries: a focused narrative review of a reduction-fixation-audit framework.Frontiers in medicine · 2026Review
- Three-Dimensional Navigated Transsacral Screw Fixation After Failed Conservative Treatment in Patients with Sacral Insufficiency Fractures: A Retrospective Observational Study with a Three-Month Follow-Up.Journal of clinical medicine · 2025Article
- Early experience with percutaneous photodynamic nails for sacral metastatic disease and insufficiency fractures: a retrospective cohort analysis of functionality and pain relief.BMC musculoskeletal disorders · 2025Article
- Review
- Feasibility and Safety of 3D-Navigated Trans-Sacral Bar Osteosynthesis for Fragility Fractures of the Sacrum: FIRST Clinical Experiences.Journal of clinical medicine · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The incidence of fragility fractures of the sacrum is increasing due to demographic changes. In this study, we introduce the 3D-navigated monoportal percutaneous sacroiliac screw fixation (PSS) as a technical advancement for treating fragility fractures of the sacrum. We included all patients who underwent the 3D-navigated monoportal PSS for fragility fractures of the sacrum. The fractures were classified using the Fragility Fractures of the Pelvis score (FFP). We provide a step-by-step illustration of the surgical technique. The objective of this study was to assess the feasibility and safety of the investigated technique. Forty-six patients (36 female, 10 male) with a median age of 81.5 years were included in the study. The fracture classification revealed 23 FFP2 (50%), 5 FFP3 (11%), and 18 FFP4 (39%) fractures. In 35 cases (76%), only transsacral screws were implanted in S1 and S2, with an average incision-to-suture time of 52.6 min. The remaining eleven patients underwent additional anterior pelvic ring fixation, lumbar instrumentation, or kyphoplasty. There were no instances of nerve root, vascular, or pelvic organ injuries. The median postoperative in-hospital stay was six days. Out of the 36 patients who were followed up, four patients required revision surgery due to screw loosening. No significant risk factor for screw loosening was identified in the multiple regression analysis. The presented monoportal PSS technique for fragility fractures of the sacrum is a promising minimally invasive approach with a low complication rate and excellent short-term outcomes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.