Evidence map›Paper›PMID 37504839›Full record

ReviewJournal of functional biomaterials2023

Engineering Antioxidant Surfaces for Titanium-Based Metallic Biomaterials.

Jithin Vishnu, Praveenkumar Kesavan, Balakrishnan Shankar, Katarzyna Dembińska, Maria Swiontek Brzezinska, Beata Kaczmarek-Szczepańska

Open access · goldAbstract readReview
In one paragraph

Review in Journal of functional biomaterials, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 20 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Jithin VishnuDepartment of Mechanical Engineering, Amrita Vishwa Vidyapeetham, Amritapuri Campus, Clappana 690525, India.ORCID 0000-0003-3704-291X
Praveenkumar KesavanDepartment of Materials Engineering, Indian Institute of Science, Bangalore 560012, India.ORCID 0000-0002-0241-6611
Balakrishnan ShankarDepartment of Mechanical Engineering, Amrita Vishwa Vidyapeetham, Amritapuri Campus, Clappana 690525, India.
Katarzyna DembińskaDepartment of Environmental Microbiology and Biotechnology, Faculty of Biological and Veterinary Sciences, Nicolaus Copernicus University in Toruń, 87-100 Toruń, Poland.
Maria Swiontek BrzezinskaDepartment of Environmental Microbiology and Biotechnology, Faculty of Biological and Veterinary Sciences, Nicolaus Copernicus University in Toruń, 87-100 Toruń, Poland.
Beata Kaczmarek-SzczepańskaDepartment of Biomaterials and Cosmetic Chemistry, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 87-100 Toruń, Poland.ORCID 0000-0002-2563-2376
Nicolaus Copernicus University · PLAmrita Vishwa Vidyapeetham · INIndian Institute of Science Bangalore · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Prolonged inflammation induced by orthopedic metallic implants can critically affect the success rates, which can even lead to aseptic loosening and consequent implant failure. In the case of adverse clinical conditions involving osteoporosis, orthopedic trauma and implant corrosion-wear in peri-implant region, the reactive oxygen species (ROS) activity is enhanced which leads to increased oxidative stress. Metallic implant materials (such as titanium and its alloys) can induce increased amount of ROS, thereby critically influencing the healing process. This will consequently affect the bone remodeling process and increase healing time. The current review explores the ROS generation aspects associated with Ti-based metallic biomaterials and the various surface modification strategies developed specifically to improve antioxidant aspects of Ti surfaces. The initial part of this review explores the ROS generation associated with Ti implant materials and the associated ROS metabolism resulting in the formation of superoxide anion, hydroxyl radical and hydrogen peroxide radicals. This is followed by a comprehensive overview of various organic and inorganic coatings/materials for effective antioxidant surfaces and outlook in this research direction. Overall, this review highlights the critical need to consider the aspects of ROS generation as well as oxidative stress while designing an implant material and its effective surface engineering.

Indexed as

antioxidantbiomaterialsreactive oxygen species (ROS)surfacestitanium

Identifiers

PMID37504839
PMCPMC10381466
OpenAlexW4382776534

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked