Evidence map›Paper›PMID 37504205›Full record

ArticleBiomimetics (Basel, Switzerland)2023

Biomimetic Design of a Tendon-Driven Myoelectric Soft Hand Exoskeleton for Upper-Limb Rehabilitation.

Rodrigo C Silva, Bruno G Lourenço, Pedro H F Ulhoa, Eduardo A F Dias, Fransergio L da Cunha, Cristiane P Tonetto, Luis G Villani, Claysson B S Vimieiro, Guilherme A Lepski, Marina Monjardim and 1 more

Abstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Rodrigo C SilvaDepartment of Mechanical Engineering, Universidade Federal do Espírito Santo, Vitória 29.075-910, Brazil.
Bruno G LourençoDepartment of Mechanical Engineering, Universidade Federal do Espírito Santo, Vitória 29.075-910, Brazil.
Pedro H F UlhoaDepartment of Electrical Engineering, Universidade Federal do Espírito Santo, Vitória 29.075-910, Brazil.
Eduardo A F DiasGraduate Program of Mechanical Engineering, Universidade Federal do Espírito Santo, Vitória 29.075-910, Brazil.
Fransergio L da CunhaDepartment of Mechanical Engineering, Universidade Federal do Espírito Santo, Vitória 29.075-910, Brazil.
Cristiane P TonettoDepartment of Mechanical Engineering, Universidade Federal do Espírito Santo, Vitória 29.075-910, Brazil.
Luis G VillaniDepartment of Mechanical Engineering, Universidade Federal do Espírito Santo, Vitória 29.075-910, Brazil.ORCID 0000-0002-1093-8479
Claysson B S VimieiroGraduate Program of Mechanical Engineering, Universidade Federal de Minas Gerais, Belo Horizonte 31270-901, Brazil.ORCID 0000-0003-1916-0517
Guilherme A LepskiDepartments of Neurology and Psychiatry, Medical School, Universidade de São Paulo, São Paulo 05403-010, Brazil.ORCID 0000-0002-9030-4192
Marina MonjardimGraduate Program of Animal Biology, Universidade Federal do Espírito Santo, Vitória 29.075-910, Brazil.
Rafhael M AndradeDepartment of Mechanical Engineering, Universidade Federal do Espírito Santo, Vitória 29.075-910, Brazil.ORCID 0000-0002-2839-3649

Funding

Coordenação de Aperfeicoamento de Pessoal de Nível Superior Finance Code 001Fundação de Amparo à Pesquisa do Espírito Santo TO 151/2021, project 2021-8GJZ6, and TO: 460/2021, project 2021-L7SZ4
6 · The paper itself

Abstract

Degenerative diseases and injuries that compromise hand movement reduce individual autonomy and tend to cause financial and psychological problems to their family nucleus. To mitigate these limitations, over the past decade, hand exoskeletons have been designed to rehabilitate or enhance impaired hand movements. Although promising, these devices still have limitations, such as weight and cost. Moreover, the movements performed are not kinematically compatible with the joints, thereby reducing the achievements of the rehabilitation process. This article presents the biomimetic design of a soft hand exoskeleton actuated using artificial tendons designed to achieve low weight, volume, and cost, and to improve kinematic compatibility with the joints, comfort, and the sensitivity of the hand by allowing direct contact between the hand palm and objects. We employed two twisted string actuators and Bowden cables to move the artificial tendons and perform the grasping and opening of the hand. With this configuration, the heavy part of the system was reallocated to a test bench, allowing for a lightweight set of just 232 g attached to the arm. The system was triggered by the myoelectric signals of the biceps captured from the user's skin to encourage the active participation of the user in the process. The device was evaluated by five healthy subjects who were asked to simulate a paralyzed hand, and manipulate different types of objects and perform grip strength. The results showed that the system was able to identify the intention of movement of the user with an accuracy of 90%, and the orthosis was able to enhance the ability of handling objects with gripping force up to 1.86 kgf.

Indexed as

biomimetic designmyoelectric controlrehabilitationsoft hand exoskeleton

Identifiers

PMID37504205
PMCPMC10807486

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.