Evidence map›Paper›PMID 37503459›Full record

ArticleJournal of neuroendovascular therapy2021

Trans-Cell Technique through Mesh of Pipeline Embolization Device: A Case Report.

Shinya Sonobe, Masayuki Ezura, Ayumi Narisawa, Naoto Kimura, Hiroshi Uenohara, Teiji Tominaga

Open access · goldAbstract readCase Reports
In one paragraph

Article in Journal of neuroendovascular therapy, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.3field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Shinya SonobeDepartment of Neurosurgery, NHO Sendai Medical Center, Sendai, Miyagi, Japan.
Masayuki EzuraDepartment of Neurosurgery, NHO Sendai Medical Center, Sendai, Miyagi, Japan.
Ayumi NarisawaDepartment of Neurosurgery, NHO Sendai Medical Center, Sendai, Miyagi, Japan.
Naoto KimuraDepartment of Neurosurgery, Iwate Prefectural Central Hospital, Morioka, Iwate, Japan.
Hiroshi UenoharaDepartment of Neurosurgery, NHO Sendai Medical Center, Sendai, Miyagi, Japan.
Teiji TominagaDepartment of Neurosurgery, Tohoku University Graduate School of Medicine, Sendai, Miyagi, Japan.
Sendai Medical Center · JPIwate Prefectural Central Hospital · JPTohoku University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: We report a case of coil embolization using trans-cell technique through mesh of a pipeline embolization device (PED). Case Presentation: A 55-year-old female developed a left cavernous carotid aneurysm (CCA) with left abducens nerve palsy. The abducens nerve palsy improved gradually after PED deployment for the aneurysm. Sixty-nine days after the procedure, the patient suddenly presented with a severe headache, left abducens nerve palsy, left eyelid edema, and left pulsatile tinnitus. Digital subtraction angiography (DSA) revealed left direct carotid cavernous fistula (dCCF) due to rupture of the aneurysm, and the patient underwent endovascular treatment. A Marathon was guided into the left internal carotid artery, and a guidewire via the Marathon passed through the mesh of the PED. Then the Marathon advanced over the guidewire into the aneurysm through the mesh of the PED, with assistance of a distal access catheter and a balloon catheter. Transarterial intra-aneurysmal coil embolization using trans-cell technique was performed, and the shunt blood flow was diminished. After subsequent transvenous embolization (TVE), the shunt blood flow disappeared, and all neurological symptoms improved. When PED is deployed linearly at a diameter 0.5 mm smaller than the nominal diameter, the average strand spacing is calculated to be approximately 0.2 mm. Since PED is a braided stent, the spacing can be large. It is theoretically reasonable for Marathon with an outer diameter of 0.59 mm to pass through the mesh of the PED. Conclusion: In some cases, trans-cell technique through mesh of PED can be performed using a small diameter microcatheter.

Indexed as

cavernous carotid aneurysmcoil embolization through Marathondirect carotid cavernous fistulapipeline embolization devicetrans-cell technique through mesh of flow diverter

Identifiers

PMID37503459
PMCPMC10370608
OpenAlexW3092216933

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.