Evidence map›Paper›PMID 37502688›Full record

ArticleJournal of neuroendovascular therapy2020

Analysis of the Anatomical Factors Affecting Ability to Navigate Penumbra Catheter through Internal Carotid Siphon.

Emi Kuriyama, Yoshikazu Matsuda, Takumi Kawaguchi, Rie Yako, Naoyuki Nakao

Abstract read
In one paragraph

Article in Journal of neuroendovascular therapy, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Aristotle 24 microwire early experience.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2023
    Article
  5. A Review of the Advancements in theFrontiers in medical technology · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Emi KuriyamaDepartment of Neurosurgery, Wakayama Medical University, Wakayama, Wakayama, Japan.
Yoshikazu MatsudaDepartment of Neurosurgery, Wakayama Medical University, Wakayama, Wakayama, Japan.
Takumi KawaguchiDepartment of Neurosurgery, Wakayama Medical University, Wakayama, Wakayama, Japan.
Rie YakoDepartment of Neurosurgery, Wakayama Medical University, Wakayama, Wakayama, Japan.
Naoyuki NakaoDepartment of Neurosurgery, Wakayama Medical University, Wakayama, Wakayama, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: The efficacy and safety of aspiration thrombectomy using Penumbra catheter with acute large vessel occlusion in the anterior circulation have been reported in previous studies. In some cases, the carotid siphon (CS) is elongated, and with this anatomy, especially where there is bifurcation of the ophthalmic artery (OA), navigation of Penumbra catheters into distal internal carotid artery (ICA) is interrupted, which is known as the 'ledge effect'. We investigate the anatomical characteristics of CS that cause interruption of navigation of the Penumbra catheter. Methods: Between January 2015 and March 2018, mechanical thrombectomy using Penumbra 60 was performed on 51 patients with middle cerebral artery (MCA) or intracranial ICA occlusion. Patients were divided into two groups: The 'ledge-effect' group those in whom the Penumbra catheter was unable to be navigated into the distal ICA through the CS, and 'no ledge-effect' group those in whom this was possible. The anatomical characteristics of CS, the diameter of ICA, diameter of OA, OA/ICA ratio and radius of the CS were evaluated using angiographical imaging. Results: The 'ledge-effect' group numbered eight cases (17%). Only the value of the CS radius was significantly smaller in the ledge-effect group (p = 0.0019), other parameters were not significantly different between the groups. The cutoff radius value was 3.62 mm. Conclusion: The most notable anatomical factor affecting possibility of navigation of the Penumbra catheter through the CS was the CS radius. This could be useful information when devices used in mechanical thrombectomy are selected.

Indexed as

carotid siphonmechanical thrombectomyPenumbra catheter

Identifiers

PMID37502688
PMCPMC10370674

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.