ArticleJournal of neuroendovascular therapy2020
Successful Retrieval of the Distal Anti-embolic Device after Carotid Stenting Using the Balloon Bridge Technique.
Article in Journal of neuroendovascular therapy, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 4 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: During carotid artery stenting (CAS), retrieval of the distal umbrella portion of the anti-embolic device (AED) could be difficult. Herein, we report a case of left CAS managed with balloon angioplasty and stent placement with successful retrieval of the umbrella portion of the AED using the balloon bridge technique after failure of retrieval with the standard technique. Case Presentation: After successful revascularization of the asymptomatic severe carotid bulb stenosis in a 62-year-old woman, we could not pass the re-sheathing catheter over the deployed stent because of the ledge effect between the guidewire of the AED and the stent mesh. However, using the balloon bridge technique, which helped minimize the ledge effect, we could advance the guiding catheter beyond the stented segment over the partially inflated balloon. The umbrella portion of the AED could be easily retrieved through the guiding catheter without complications. Conclusion: During CAS, the balloon bridge technique could be used to retrieve the AED after failure of retrieval with the standard techniques.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.