Evidence map›Paper›PMID 37500931›Full record

ArticleArchives of orthopaedic and trauma surgery2023

Analysis of the effects of intraoperative warming devices on surgical site infection in elective hip arthroplasty using a large nationwide database.

Seung Hoon Kim, Suk-Yong Jang, Yonghan Cha, Bo-Yeon Kim, Hyo-Jung Lee, Gui-Ok Kim

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 78% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Seung Hoon KimDepartment of Preventive Medicine, Eulji University School of Medicine, Daejeon, South Korea.
Suk-Yong JangDepartment of Healthcare Management, Graduate School of Public Health, Yonsei University, Seoul, South Korea.
Yonghan ChaDepartment of Orthopaedic Surgery, Daejeon Eulji Medical Center, Eulji University School of Medicine, 95 Dunsan Seoro, Seo-Gu, Daejeon, 35233, South Korea. naababo77@naver.com.ORCID http://orcid.org/0000-0002-7616-6694
Bo-Yeon KimHealthcare Review and Assessment Committee, Health Insurance Review and Assessment Service, Wonju, South Korea.
Hyo-Jung LeeQuality Assessment Department, Health Insurance Review and Assessment Service, Wonju, South Korea.
Gui-Ok KimQuality Assessment Department, Health Insurance Review and Assessment Service, Wonju, South Korea.
Health Insurance Review and Assessment Service · KREulji University · KRYonsei University Health System · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe aim of our study is to analyze the association of usage and type of warming device with the risk of surgical site infection (SSI) in patients who underwent hip arthroplasty, and to analyze the factors that increase the risk of SSI if the warming device is not used. MATERIALS AND

methodsThis retrospective cross-sectional study identified subjects from data of "Evaluation of the Appropriate Use of Prophylactic Antibiotics". Included patients were defined as those who underwent elective unilateral hip hemiarthroplasty or total hip arthroplasty (THA). Patients were classified into no intraoperative warming device, forced air warming devices, and devices using conduction. Multiple logistic regression analysis was conducted to estimate adjusted odds ratios (aORs) and 95% confidence intervals (CIs) to assess the association between warming devices and SSI.

resultsA total of 3945 patients met the inclusion criteria. Compared to those who received an intraoperative warming device, the odds of developing SSI were 1.9 times higher in those who did not receive intraoperative warming devices (aOR 1.9; 95% CI 1.1-3.6). The risk of SSI was 2.2 times higher with forced air warming devices compared to devices using conduction but this difference was not statistically significant (aOR 2.2; 95% CI 0.7-6.8). The risk of SSI increased in males (aOR 2.8; 95% CI 1.1-7.2), in patients under 70 years of age (aOR 4.4; 95% CI 1.6-10.4), in patients with a Charlson`s comorbidity index of 2 or higher (aOR 3.3; 95% CI 1.3-8.7), and in patients who underwent THA (aOR 3.8; 95% CI 1.7-8.3) when intraoperative warming devices were not used.

conclusionsThe use of intraoperative active warming devices is highly recommended to prevent SSI during elective hip arthroplasty. In particular, male patients younger than 70 years, those with a high CCI, and those undergoing THA are at significantly increased risk of SSI if intraoperative active warming devices are not used. Intraoperative warming device using conduction is likely superior to forced air warming device, but further studies are needed to confirm this.

Indexed as

Arthroplasty, Replacement, HipArthroplasty, Replacement, KneeCross-Sectional StudiesHumansMaleRetrospective StudiesRisk FactorsSurgical Wound InfectionHip arthroplastyInfectionRisk factorsWarming

Identifiers

PMID37500931
OpenAlexW4385331187

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.