Evidence map›Paper›PMID 37500577›Full record

ArticleKorean journal of radiology2023

Treatment Outcomes of Percutaneous Radiofrequency Ablation for Hepatocellular Carcinomas: Effects of the Electrode Type and Placement Method.

Jiyeon Park, Min Woo Lee, Soo Hyun Ahn, Seungchul Han, Ji Hye Min, Dong Ik Cha, Kyoung Doo Song, Tae Wook Kang, Hyunchul Rhim

Open access · hybridAbstract read
In one paragraph

Article in Korean journal of radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Jiyeon ParkDepartment of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-0353-0109
Min Woo LeeDepartment of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID 0000-0001-9048-9011
Soo Hyun AhnDepartment of Mathematics, Ajou University, Suwon, Republic of Korea.ORCID 0000-0001-5016-5469
Seungchul HanDepartment of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-7276-0370
Ji Hye MinDepartment of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-8496-6771
Dong Ik ChaDepartment of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID 0000-0003-3271-6532
Kyoung Doo SongDepartment of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-2767-3622
Tae Wook KangDepartment of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-0725-8317
Hyunchul RhimDepartment of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-9737-0248
Samsung Medical Center · KRSamsung (South Korea) · KRAjou University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo investigate the association among the electrode placement method, electrode type, and local tumor progression (LTP) following percutaneous radiofrequency ablation (RFA) for small hepatocellular carcinomas (HCCs) and to assess the risk factors for LTP. MATERIALS AND

methodsIn this retrospective study, we enrolled 211 patients, including 150 males and 61 females, who had undergone ultrasound-guided RFA for a single HCC < 3 cm. Patients were divided into four combination groups of the electrode type and placement method: 1) tumor-puncturing with an internally cooled tip (ICT), 2) tumor-puncturing with an internally cooled wet tip (ICWT), 3) no-touch with ICT, and 4) no-touch with ICWT. Univariable and multivariable Cox proportional-hazards regression analyses were performed to evaluate the risk factors for LTP. The major RFA-related complications were assessed.

resultsOverall, 83, 34, 80, and 14 patients were included in the ICT, ICWT, no-touch with ICT, and no-touch with ICWT groups, respectively. The cumulative LTP rates differed significantly among the four groups. Compared to tumor puncturing with ICT, tumor puncturing with ICWT was associated with a lower LTP risk (adjusted hazard ratio [aHR] = 0.11, 95% confidence interval [CI] = 0-0.88,

conclusionICWT was associated with a lower LTP rate compared to ICT when performing tumor-puncturing RFA. An insufficient ablation margin was a risk factor for LTP.

Indexed as

Carcinoma, HepatocellularCatheter AblationLiver NeoplasmsRadiofrequency AblationElectrodesFemaleHumansMaleRetrospective StudiesTreatment OutcomeHepatocellular carcinomaInternally cooled tipInternally cooled wet tipLocal tumor progressionRadiofrequency ablation

Identifiers

PMID37500577
PMCPMC10400371
OpenAlexW4385250132

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.