Evidence map›Paper›PMID 37497506›Full record

ArticleBiomedical optics express2023

Automated inter-device 3D OCT image registration using deep learning and retinal layer segmentation.

David Rivas-Villar, Alice R Motschi, Michael Pircher, Christoph K Hitzenberger, Markus Schranz, Philipp K Roberts, Ursula Schmidt-Erfurth, Hrvoje Bogunović

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Medical image registration and its application in retinal images: a review.Visual computing for industry, biomedicine, and art · 2024
    Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 4 countries.

David Rivas-VillarCentro de investigacion CITIC, Universidade da Coruña, 15071 A Coruña, Spain.ORCID https://orcid.org/0000-0001-7824-8098
Alice R MotschiMedical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria.ORCID https://orcid.org/0000-0003-0804-2304
Michael PircherMedical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria.ORCID https://orcid.org/0000-0001-9285-7527
Christoph K HitzenbergerMedical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria.ORCID https://orcid.org/0000-0002-6608-8821
Markus SchranzMedical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria.
Philipp K RobertsMedical University of Vienna, Department of Ophthalmology and Optometry, Vienna, Austria.
Ursula Schmidt-ErfurthMedical University of Vienna, Department of Ophthalmology and Optometry, Vienna, Austria.
Hrvoje BogunovićMedical University of Vienna, Department of Ophthalmology and Optometry, Christian Doppler Lab for Artificial Intelligence in Retina, Vienna, Austria.ORCID https://orcid.org/0000-0002-9168-0894
Centre for Biomedical Engineering and Physics · SEMedical University of Vienna · ATUniversidade da Coruña · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Optical coherence tomography (OCT) is the most widely used imaging modality in ophthalmology. There are multiple variations of OCT imaging capable of producing complementary information. Thus, registering these complementary volumes is desirable in order to combine their information. In this work, we propose a novel automated pipeline to register OCT images produced by different devices. This pipeline is based on two steps: a multi-modal 2D en-face registration based on deep learning, and a Z-axis (axial axis) registration based on the retinal layer segmentation. We evaluate our method using data from a Heidelberg Spectralis and an experimental PS-OCT device. The empirical results demonstrated high-quality registrations, with mean errors of approximately 46 µm for the 2D registration and 9.59 µm for the Z-axis registration. These registrations may help in multiple clinical applications such as the validation of layer segmentations among others.

Identifiers

PMID37497506
PMCPMC10368062
OpenAlexW4379473376

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked