Evidence map›Paper›PMID 37497492›Full record

ArticleBiomedical optics express2023

Handheld photoacoustic imaging of indocyanine green clearance for real-time quantitative evaluation of liver reserve function.

Hai Zhang, Si-Lue Zeng, Yun-Zhu Wu, Ruo-Xin Zhang, Liang-Jian Liu, Qiang Xue, Jing-Qin Chen, Kenneth K Y Wong, Jin-Feng Xu, Ya-Guang Ren and 2 more

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.2field-weighted citation impact, top 53% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 2 citations in OpenAlex.

  1. Review
  2. Biomedical optics express · 2026
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 5 institutions in 2 countries.

Hai ZhangDepartment of Ultrasound, Shenzhen People's Hospital, The Second Clinical College of Jinan University, The First Affiliated Hospital of Southern University of Science and Technology, Shenzhen 518020, China.
Si-Lue ZengDepartment of Hepatobiliary Surgery I, Zhujiang Hospital, Southern Medical University, Guangzhou 510280, China.
Yun-Zhu WuDepartment of Ultrasound, Shenzhen People's Hospital, The Second Clinical College of Jinan University, The First Affiliated Hospital of Southern University of Science and Technology, Shenzhen 518020, China.
Ruo-Xin ZhangShen Zhen Bay Laboratory, Guang Ming, ShenZhen,518000, China.
Liang-Jian LiuResearch Laboratory for Biomedical Optics and Molecular Imaging, CAS Key Laboratory of Health Informatics, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Qiang XueDepartment of Ultrasound, Shenzhen People's Hospital, The Second Clinical College of Jinan University, The First Affiliated Hospital of Southern University of Science and Technology, Shenzhen 518020, China.
Jing-Qin ChenResearch Laboratory for Biomedical Optics and Molecular Imaging, CAS Key Laboratory of Health Informatics, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Kenneth K Y WongThe University of Hong Kong, Department of Electrical and Electronic Engineering, Hong Kong, China.ORCID https://orcid.org/0000-0003-3668-3539
Jin-Feng XuDepartment of Ultrasound, Shenzhen People's Hospital, The Second Clinical College of Jinan University, The First Affiliated Hospital of Southern University of Science and Technology, Shenzhen 518020, China.
Ya-Guang RenResearch Laboratory for Biomedical Optics and Molecular Imaging, CAS Key Laboratory of Health Informatics, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Chi-Hua FangDepartment of Hepatobiliary Surgery I, Zhujiang Hospital, Southern Medical University, Guangzhou 510280, China.
Cheng-Bo LiuResearch Laboratory for Biomedical Optics and Molecular Imaging, CAS Key Laboratory of Health Informatics, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.ORCID https://orcid.org/0000-0001-7565-2044
Chinese Academy of Sciences · CNSouthern University of Science and Technology · CNShenzhen Bay Laboratory · CNSouthern Medical University · CNUniversity of Hong Kong · HK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Preoperative assessment of liver function reserve (LFR) is essential for determining the extent of liver resection and predicting the prognosis of patients with liver disease. In this paper, we present a real-time, handheld photoacoustic imaging (PAI) system-based noninvasive approach for rapid LFR assessment. A linear-array ultrasound transducer was sealed in a housing filled with water; its front end was covered with a plastic wrap. This PAI system was first implemented on phantoms to confirm that the photoacoustic (PA) intensity of indocyanine green (ICG) in blood reflects the concentration of ICG in blood.