Evidence map›Paper›PMID 37497041›Full record

ArticleFrontiers in human neuroscience2023

Development of split-force-controlled body weight support (SF-BWS) robot for gait rehabilitation.

Asuka Takai, Tatsuya Teramae, Tomoyuki Noda, Koji Ishihara, Jun-Ichiro Furukawa, Hiroaki Fujimoto, Megumi Hatakenaka, Nobukazu Fujita, Akihiro Jino, Yuichi Hiramatsu and 2 more

Open access · goldAbstract read
In one paragraph

Article in Frontiers in human neuroscience, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.3field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 4 institutions in 1 country.

Asuka Takai *Department of Brain Robot Interface, Brain Information Communication Research Laboratory Group, Advanced Telecommunications Research Institute International (ATR), Kyoto, Japan.
Tatsuya Teramae *Department of Brain Robot Interface, Brain Information Communication Research Laboratory Group, Advanced Telecommunications Research Institute International (ATR), Kyoto, Japan.
Tomoyuki NodaDepartment of Brain Robot Interface, Brain Information Communication Research Laboratory Group, Advanced Telecommunications Research Institute International (ATR), Kyoto, Japan.
Koji IshiharaDepartment of Brain Robot Interface, Brain Information Communication Research Laboratory Group, Advanced Telecommunications Research Institute International (ATR), Kyoto, Japan.
Jun-Ichiro FurukawaDepartment of Brain Robot Interface, Brain Information Communication Research Laboratory Group, Advanced Telecommunications Research Institute International (ATR), Kyoto, Japan.
Hiroaki FujimotoNeurorehabilitation Research Institute, Morinomiya Hospital, Osaka, Japan.
Megumi HatakenakaNeurorehabilitation Research Institute, Morinomiya Hospital, Osaka, Japan.
Nobukazu FujitaNeurorehabilitation Research Institute, Morinomiya Hospital, Osaka, Japan.
Akihiro JinoNeurorehabilitation Research Institute, Morinomiya Hospital, Osaka, Japan.
Yuichi HiramatsuNeurorehabilitation Research Institute, Morinomiya Hospital, Osaka, Japan.
Ichiro MiyaiNeurorehabilitation Research Institute, Morinomiya Hospital, Osaka, Japan.
Jun MorimotoDepartment of Brain Robot Interface, Brain Information Communication Research Laboratory Group, Advanced Telecommunications Research Institute International (ATR), Kyoto, Japan.
Morinomiya Hospital · JPAdvanced Telecommunications Research Institute International · JPKyoto College of Graduate Studies for Informatics · JPTokyo Metropolitan University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study introduces a body-weight-support (BWS) robot actuated by two pneumatic artificial muscles (PAMs). Conventional BWS devices typically use springs or a single actuator, whereas our robot has a split force-controlled BWS (SF-BWS), in which two force-controlled actuators independently support the left and right sides of the user's body. To reduce the experience of weight, vertical unweighting support forces are transferred directly to the user's left and right hips through a newly designed harness with an open space around the shoulder and upper chest area to allow freedom of movement. A motion capture evaluation with three healthy participants confirmed that the proposed harness does not impede upper-body motion during laterally identical force-controlled partial BWS walking, which is quantitatively similar to natural walking. To evaluate our SF-BWS robot, we performed a force-tracking and split-force control task using different simulated load weight setups (40, 50, and 60 kg masses). The split-force control task, providing independent force references to each PAM and conducted with a 60 kg mass and a test bench, demonstrates that our SF-BWS robot is capable of shifting human body weight in the mediolateral direction. The SF-BWS robot successfully controlled the two PAMs to generate the desired vertical support forces.

Indexed as

body weight shiftbody weight supportcenter of pressureforce controlpneumatic artificial muscle

Identifiers

PMID37497041
PMCPMC10366359
OpenAlexW4383912710

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked