Evidence map›Paper›PMID 37496729›Full record

ArticleReaction chemistry & engineering2023

Efficient degassing and ppm-level oxygen monitoring flow chemistry system.

Paulius Baronas, Jacob Lynge Elholm, Kasper Moth-Poulsen

Abstract read
In one paragraph

Article in Reaction chemistry & engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Paulius BaronasThe Institute of Materials Science of Barcelona, ICMAB-CSIC Bellaterra 08193 Barcelona Spain.ORCID https://orcid.org/0000-0002-4141-1485
Jacob Lynge ElholmThe Institute of Materials Science of Barcelona, ICMAB-CSIC Bellaterra 08193 Barcelona Spain.ORCID https://orcid.org/0000-0002-6441-1664
Kasper Moth-PoulsenThe Institute of Materials Science of Barcelona, ICMAB-CSIC Bellaterra 08193 Barcelona Spain.ORCID https://orcid.org/0000-0003-4018-4927

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Low oxygen levels are critical for a long range of chemical transformations carried out in both flow and batch chemistry. Here, we present an inline continuous flow degassing system based on a gas-permeable membrane inside a vacuum chamber for achieving and monitoring ppm-level oxygen concentrations in solutions. The oxygen presence was monitored with a molecular oxygen probe and a continuously running UV-vis spectrometer. An automated setup for discovering optimal reaction conditions for minimal oxygen presence was devised. The parameters tested were: flow rate, vacuum pressure, solvent back-pressure, tube material, tube length and solvent oxygen solubility. The inline degassing system was proven to be effective in removing up to 99.9% of ambient oxygen from solvents at a flow rate of 300 μl min

Identifiers

PMID37496729
PMCPMC10366651

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.