Evidence map›Paper›PMID 37494135›Full record

ArticleJournal of applied clinical medical physics2023

Transmission probability filter optimization for Agility MLC in Monaco treatment planning system.

Lena Thewes, Miriam Eckl, Frank Schneider

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Lena ThewesDepartment of Radiation Oncology, University Medical Centre Mannheim, University of Heidelberg, Mannheim, Germany.
Miriam EcklDepartment of Radiation Oncology, University Medical Centre Mannheim, University of Heidelberg, Mannheim, Germany.
Frank SchneiderDepartment of Radiation Oncology, University Medical Centre Mannheim, University of Heidelberg, Mannheim, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In the Monte Carlo-based treatment planning system (TPS) Monaco, transmission probability filters (TPF) are utilized to describe the transmission through the multi leaf collimator (MLC). By having knowledge of the TPF parameters for various photon beam energies, adjusting the MLC transmission parameters becomes easier, enhancing the accuracy of the Monte Carlo algorithm in achieving a dose distribution that closely aligns with the irradiated dose at the Versa HD linear accelerator (linac). The objective of this study was to determine the TPF parameters for 6MV, 10MV, 6MV flattening filter free (FFF) and 10MV FFF for a Versa HD linac equipped with Agility MLC. The TPF parameters were adjusted using point dose measurements and vendor-provided fields specifically designed to fine-tune the MLC. After adjusting the TPF parameters, a gamma passing rate (GPR) analysis was conducted on 25 treatment plans to ensure that the Monte Carlo model, with the updated TPF parameters, accurately matched the actual linac delivery. The TPF values ranged from 0.0018 to 0.0032 for leaf transmission and 1.15 to 1.25 for Leaf Tip leakage across the different energies. The average GPR ranged from 97.8% for 10MV FFF to 98.5% for 6MV photon energies. Additionally, the TPF parameters for 6MV obtained in this study were consistent with previously published TPF values for 6MV photon energy. Hence, it was concluded that optimizing the TPF does not need to be performed for every individual Versa HD linac with Agility MLC. Instead, the published parameters can be applied to other Versa HD linacs to enhance clinical accuracy. In conclusion, this study determined the TPF parameters for 6MV and previously unpublished photon energies 10MV, 6MV FFF and 10MV FFF. These parameters can be easily transferred to other facilities, resulting in improved agreement between the dose distribution from the TPS and the linac.

Indexed as

Radiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedHumansMonte Carlo MethodParticle AcceleratorsPhantoms, ImagingRadiotherapy DosageMLC transmission in Monaco TPStransmission probability filters

Identifiers

PMID37494135
PMCPMC10476981

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.