ArticleBMJ open ophthalmology2023
Comparing Ahmed-FP7 to Baerveldt-250 and Baerveldt-350 surgical outcomes: 1-year results from a retrospective cohort study leveraging the electronic health record.
Article in BMJ open ophthalmology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
objectiveTo compare outcomes following Ahmed-FP7 (AGI-FP7), Baerveldt-250mm METHODS AND ANALYSIS: Retrospective cohort study comprising 800 eyes from 800 individuals who underwent surgery 1 January 2016-31 December 2020 at a tertiary-care institution. Data were extracted from standardised fields in the electronic health record. Primary outcome was failure (defined as intraocular pressure (IOP) ≤5 mm Hg or >18 mm Hg or reduction <20% at two consecutive visits from month 3 onwards; or visual acuity (VA) loss ≥3 lines; or return to the operating room (OR)). Secondary outcomes were IOP, VA, number of follow-up visits and return to the OR.
resultsA total of 523 AGI-FP7, 133 BGI-250 and 144 BGI-350 cases were analysed. The AGI-FP7 group was more likely to be younger and diagnosed with secondary glaucoma, with a higher mean baseline IOP (28.5±12.2 vs 22.0±7.7 mm Hg in BGI-250 and 23.4±9.0 in BGI-350, p<0.001). Cumulative failure rate at month 12 was 30% (AGI-FP7) vs 39% (BGI-250) vs 33% (BGI-350, p=0.159). Mean IOP at month 12 was lower in the BGI-350 group compared with AGI-FP7 (12.4±4.4 vs 14.8±5.6 mm Hg, p=0.003) but not BGI-250 (vs 13.1±4.6, p=0.710). Target IOP was achieved in 71% of AGI-FP7, 66% BGI-250, and 76% BGI-350. VA loss and rates of return to the OR did not differ between groups. Both BGI-250 and BGI-350 had more follow-up visits than AGI-FP7 (p<0.001).
conclusionThese three glaucoma drainage devices performed similarly within 1 year, with no difference in failure rates despite differing baseline patient characteristics.