Ambient light exposure of photostimulable phosphor plates: is there a safe limit for acceptable image quality?

Matheus Sampaio-Oliveira, Luiz Eduardo Marinho-Vieira, Francisco Haiter-Neto, Deborah Q Freitas, Matheus L Oliveira

Abstract read
In one paragraph

Article in Dento maxillo facial radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Matheus Sampaio-OliveiraDepartment of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil.ORCID 0000-0002-0414-6395
Luiz Eduardo Marinho-VieiraDepartment of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil.ORCID 0000-0001-5701-5164
Francisco Haiter-NetoDepartment of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil.ORCID 0000-0002-5610-8307
Deborah Q FreitasDepartment of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil.ORCID 0000-0002-1425-5966
Matheus L OliveiraDepartment of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil.ORCID 0000-0002-8054-8759

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo subjectively assess radiographs obtained with photostimulable phosphor (PSP) plates exposed to clinical levels of ambient light prior to read-out to potentially set a safe limit for acceptable image quality. METHODS AND MATERIALS: Six dental regions of a dry human skull were X-rayed using PSP plates from VistaScan and Express under four exposure times: 0.1, 0.2, 0.32, and 0.4 s. Before read-out, the PSP plates were exposed to ambient light for 0, 5, 10, 30, 60, and 90 s. Six observers were asked to classify the 288 resulting radiographs as acceptable or unacceptable based on the identification of anatomical structures and global image quality. The number of answers classifying radiographs as unacceptable was used to calculate a rejection rate; a pairwise comparison for better image quality was further conducted among radiographs considered acceptable. Reproducibility was tested by having 25% of all experimental groups reassessed.

resultsIntra- and interobserver agreement ranged from 0.87 to 1.00 and from 0.81 to 0.92, respectively. Exposure of PSP plates to ambient light increased rejection rates mostly as of 10 s. In the pairwise comparison, subtle differences were observed between radiographs obtained with PSP plates not exposed and those exposed to ambient light for 5 s.

conclusionsAmbient light exposure of PSP plates impairs the image quality of radiographs. A safe limit of ambient light exposure of 5 s for VistaScan and Express should be considered. Ambient light exposure of PSP plates within safe limits can avoid retakes and reduce unnecessary patient exposure to X-rays.

Indexed as

Radiographic Image EnhancementRadiography, Dental, DigitalHumansReproducibility of ResultsSkullX-Raysdigital dental radiographylightsentiment analysisvisual perception

Identifiers

PMID37493608
PMCPMC10552132

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.