Evidence map›Paper›PMID 37488581›Full record

ArticleBMC oral health2023

Scanning accuracy of an intraoral scanner according to different inlay preparation designs.

Yeri Park, Jae-Hoon Kim, Jeong-Kil Park, Sung-Ae Son

Abstract read
In one paragraph

Article in BMC oral health, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yeri ParkDepartment of Conservative Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.
Jae-Hoon KimDepartment of Dental Education, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Republic of Korea.
Jeong-Kil ParkDepartment of Conservative Dentistry, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Geumo-Ro 20, Mulgeum-Eup, Box 50612, Yangsan, Republic of Korea.
Sung-Ae SonDepartment of Conservative Dentistry, Dental and Life Science Institute, School of Dentistry, Pusan National University, Dental Research Institute, Geumo-Ro 20, Mulgeum-Eup, Box 50612, Yangsan, Republic of Korea. songae76@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe accuracy of intraoral scanning plays a crucial role in the workflow of computer-assisted design/computer-assisted manufacturing. However, data regarding scanning accuracy for inlay preparation designs are lacking. The purpose of this in vitro study was to evaluate the influence of the depth of the occlusal cavity and width of the gingival floor of the proximal box on the trueness and precision of intraoral scans for inlay restoration.

methodsArtificial teeth were used in this study. Four types of preparations for mesio-occlusal inlay were performed on each #36 artificial tooth depending on two different depths of the occlusal cavity (1 mm and 2 mm) and widths of the gingival floor of the proximal box (1.5 mm and 2.5 mm). Artificial teeth were scanned 10 times each with Cerec Primescan AC, and another scan was performed subsequently with a laboratory scanner as a reference (n = 10). Standard tessellation language files were analyzed using a three-dimensional analysis software program. Experimental data were analyzed using two-way analysis of variance and the Bonferroni multiple comparison test.

resultsThe narrow shallow group had significantly higher deviation values for trueness than the wide deep group (p < 0.05). The wide deep group had the lowest average deviation value for trueness and there was no significant difference between the narrow deep and wide shallow groups (p > 0.05). For the mean maximum positive deviation, the wide groups had significantly lower values than the narrow groups (p < 0.05). Trueness was affected by both the width and depth(p < 0.05), whereas the mean maximum positive deviation was affected by the width (p < 0.05). The mean maximum negative deviation was affected by all three factors (p < 0.05). Precision was affected by the depth and the interaction between the depth of the occlusal cavity and width of the gingival floor (p < 0.05).

conclusionsThe design of different inlay cavity configurations affected the accuracy of the digital intraoral scanner. The highest average deviation for trueness was observed in the narrow shallow group and the lowest in the wide deep group. With regard to precision, the narrow shallow group showed the lowest average deviation, and the narrow deep group showed highest value.

Indexed as

Dental CariesInlaysComputer-Aided DesignDental CareGingivaHumansAccuracyCAD/CAMInlay designsIntraoral scannerPrecisionTrueness

Identifiers

PMID37488581
PMCPMC10367335

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.