Evidence map›Paper›PMID 37486463›Full record

ArticleEuropean radiology experimental2023

Influence of contrast medium on tophus detection using dual-energy CT: phantom study and clinical illustration.

Maximilian Kotlyarov, Jürgen Mews, Sevtap Tugce Ulas, Katharina Ziegeler, Bernd Hamm, Torsten Diekhoff

Open access · goldAbstract read
In one paragraph

Article in European radiology experimental, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Maximilian KotlyarovDepartment of Radiology, Charité - Universitätsmedizin Berlin, Campus Mitte, Humboldt-Universität Zu Berlin, Freie Universität Berlin, 10117, Berlin, Germany. maximilian.kotlyarov@charite.de.ORCID 0000-0002-2545-686X
Jürgen MewsCanon Medical Systems, Europe BV, Zoetermeer, Netherlands.
Sevtap Tugce UlasDepartment of Radiology, Charité - Universitätsmedizin Berlin, Campus Mitte, Humboldt-Universität Zu Berlin, Freie Universität Berlin, 10117, Berlin, Germany.
Katharina ZiegelerDepartment of Radiology, Charité - Universitätsmedizin Berlin, Campus Mitte, Humboldt-Universität Zu Berlin, Freie Universität Berlin, 10117, Berlin, Germany.
Bernd HammDepartment of Radiology, Charité - Universitätsmedizin Berlin, Campus Mitte, Humboldt-Universität Zu Berlin, Freie Universität Berlin, 10117, Berlin, Germany.
Torsten DiekhoffDepartment of Radiology, Charité - Universitätsmedizin Berlin, Campus Mitte, Humboldt-Universität Zu Berlin, Freie Universität Berlin, 10117, Berlin, Germany.
Humboldt-Universität zu Berlin · DECanon (Netherlands) · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo investigate the influence of iodinated contrast medium (ICM) on detection of monosodium urate (MSU) with dual-energy computed tomography (DECT) in two types of phantoms and demonstrate an example patient for clinical illustration.

methodsApproval is by the institutional review board, and written informed consent was obtained. A grid-like and a biophantom with 25 suspensions containing different concentrations of ICM (0 to 2%) and MSU (0 to 50%) were prepared and scanned with sequential single-source DECT using established methodology. Ascending orders of tube currents were applied at 80 kVp (16.5 to 220.0 mAs) and 135 kVp (2.75 to 19.25 mAs). Volume and mass measurements were performed using clinical gout software (dual-energy decomposition analysis). Numbers of true-positive and false-positive MSU detections were recorded and compared for different ICM concentrations. We demonstrate a patient with gouty arthritis for clinical illustration.

resultsEffects of ICM on MSU detection varied with the amount of iodine. Lower ICM concentrations (0.25 and 0.50%) improved detection of small uric acid concentrations of 35 to 45% in comparison to scans without ICM. However, high ICM concentrations (1 and 2%) almost completely precluded MSU detection for all MSU concentrations investigated. In a patient with gouty arthritis, tophi in the wrist were only detected after intravenous ICM administration.

conclusionsExploring multimodal DECT for arthritis imaging, enhancement of ICM influences tophus detection. It can help in visualizing previously undetected MSU depositions but, with too strong enhancement, also obscure tophi. RELEVANCE STATEMENT: Use of iodinated contrast media in dual-energy CT might help in visualizing previously undetected uric acid depositions but, with too strong enhancement, obscure gouty tophi. KEY POINTS: • Iodine significantly influences the uric acid crystal detection in systematic phantom studies. • Lower iodine concentrations improved detection of low and medium uric acid concentrations. • High concentrations of iodine hampered detection of all uric acid concentrations.

Indexed as

Arthritis, GoutyIodineContrast MediaHumansTomography, X-Ray ComputedUric AcidContrast MediaIodineUric AcidArthritis (gouty)Contrast mediaPhantoms (imaging)Tomography (x-ray computed)Uric acid

Identifiers

PMID37486463
PMCPMC10366067
OpenAlexW4385186866

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.