Evidence map›Paper›PMID 37485208›Full record

ArticleCureus2023

Non-channeled Video Laryngoscopy as an Alternative to Conventional Laryngoscopy for Intubating Adult Patients in the Intensive Care Unit.

Aparna Shukla, Ravi Shanker, Vipin K Singh, Gyan Prakash Singh, Tanushree Srivastava

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 6 citations in OpenAlex.

  1. Pooled it
  2. [Video laryngoscopy in the intensive care unit-A current assessment].Medizinische Klinik, Intensivmedizin und Notfallmedizin · 2025
    Review
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Aparna ShuklaAnaesthesiology, King George's Medical University, Lucknow, IND.
Ravi ShankerAnaesthesiology, King George's Medical University, Lucknow, IND.
Vipin K SinghAnaesthesiology, King George's Medical University, Lucknow, IND.
Gyan Prakash SinghAnaesthesiology, King George's Medical University, Lucknow, IND.
Tanushree SrivastavaAnaesthesiology, Integral Institute of Medical Sciences and Research, Lucknow, IND.
King George's Medical University · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Endotracheal intubation in the intensive care unit (ICU) is often a risky procedure due to the emergency situation, unstable condition of the patient, and technical problems such as inadequate positioning. Several new techniques, such as video laryngoscopy, have been developed recently to improve the success rate of first-pass intubations and reduce complications. We conducted this study to compare a non-channeled reusable video laryngoscope BPL VL-02 (manufactured by BPL Medical Technologies, Bangalore, India) with a conventional laryngoscope for intubation of adult patients in the ICU. Methodology A total of 72 ICU patients were randomly allocated to be intubated with either conventional direct laryngoscopy via Macintosh blade (group A) or video laryngoscopy with BPL VL-02 (group B). All patients were intubated by the primary investigator and the assistant noted the following parameters: the total number of intubation attempts, total duration of intubation, assistance or alternative technique required, Cormack Lehane grading, and any complications. Results There was no significant difference in the Cormack Lehane grading, number of attempts, or complications between the two groups. On comparing the assistance required during intubation in patients, it was observed that four (11.11%) patients in group A and seven (19.44%) patients in group B needed backward, upward, and rightward pressure on the larynx assistance during intubation. In five (13.89%) patients in group B, Stylet was required during intubation. The difference was statistically significant (p = 0.0308). The video laryngoscopy group (group B) had a longer mean duration of intubation (64.36 ± 6.28 seconds) compared to group A (45.72 ± 11.45 seconds), and the difference was statistically significant (p < 0.0001). Conclusions Non-channeled video laryngoscope (BPL VL-02) is not a suitable alternative to conventional direct laryngoscopy with a Macintosh blade in terms of successful first-pass intubation, total duration of intubation, and assistance required.

Indexed as

conventional laryngoscopyintensive care unit (icu)intubationmacintosh laryngoscopevideo laryngoscopevideo laryngoscopy (vl)

Identifiers

PMID37485208
PMCPMC10359833
OpenAlexW4381664238

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.