Evidence map›Paper›PMID 37484057›Full record

ArticleHealth science reports2023

Pelvic radiation dose measurement for trauma patients in multifield radiographic examinations: A phantom-based TLD dosimetry study.

Ameneh Peiro, Nahid Chegeni, Amir Danyaei, Jafar Fatahiasl, Marziyeh Tahmasbi

Open access · goldAbstract read
In one paragraph

Article in Health science reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Ameneh PeiroDepartment of Medical Physics, School of Medicine Ahvaz Jundishapur University of Medical Sciences Ahvaz Iran.
Nahid ChegeniDepartment of Medical Physics, School of Medicine Ahvaz Jundishapur University of Medical Sciences Ahvaz Iran.ORCID https://orcid.org/0000-0002-6373-5456
Amir DanyaeiDepartment of Medical Physics, School of Medicine Ahvaz Jundishapur University of Medical Sciences Ahvaz Iran.
Jafar FatahiaslDepartment of Radiologic Technology, School of Allied Medical Sciences Ahvaz Jundishapur University of Medical Sciences Ahvaz Iran.
Marziyeh TahmasbiDepartment of Radiologic Technology, School of Allied Medical Sciences Ahvaz Jundishapur University of Medical Sciences Ahvaz Iran.ORCID 0000-0003-0797-5049
Ahvaz Jundishapur University of Medical Sciences · IR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Aims: Trauma patients often suffer from multiple injuries and require undergoing various radiography which is referred to as multifield radiographic examinations. Protective measures may be ignored for these examinations due to stressful emergency situations or patients' conditions. This study was conducted to evaluate the scattered doses received by the pelvis during different common multifield radiographic examinations with an emphasis on field size adjustment. Methods: A whole-body phantom, PBU-50, resembling the body mass, was used to carry out the common examinations for trauma patients (extremities, skull, chest, abdomen, pelvis, femur, and lumbar radiography), using a Pars Pad X-ray machine. To measure the primary entrance skin doses, three calibrated GR 200 thermoluminescence dosimeter (TLD) chips were placed in the central X-ray beam of scanned organs. Three TLDs were also placed on the pelvis symphysis pubis to measure the scattered dose received by the pelvis due to each carried-out radiography for standard and clinically used field sizes. A Harshaw 3500 TLD Reader was used to read the chips. TLD readouts (nano-Coulomb) were converted to dose (milli Gray [mGy]) using the predefined calibration curve. Results: The scattered doses to the pelvis due to scanning a single organ differed from 0.80 to 1.70, and 0.82 to 4.09 mGy for standard and clinically used field sizes, respectively. The scattered doses to the pelvis in multifield examinations varied from 0.80 to 8.43 and 0.82 to 13.6 mGy for standard and clinically used field sizes, respectively, depending on the number of scanned organs and their distances from the pelvis. Conclusions: Multiple and repeated radiographs combined with insufficient protective measures can increase the patient's dose. The findings indicate that the scattered doses received by the pelvis can exceed the reference values in multifield radiography, especially if the radiation field is not restricted properly to the scanned organ.

Indexed as

multifield radiographypelvis doseradiation field sizescattered doseTLD dosimetrytrauma patients

Identifiers

PMID37484057
PMCPMC10356977
OpenAlexW4384936712

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked