Evidence map›Paper›PMID 37481514›Full record

ArticleBMC medical research methodology2023

Comparison of discrimination and calibration performance of ECG-based machine learning models for prediction of new-onset atrial fibrillation.

Giovanni Baj, Ilaria Gandin, Arjuna Scagnetto, Luca Bortolussi, Chiara Cappelletto, Andrea Di Lenarda, Giulia Barbati

Open access · goldAbstract read
In one paragraph

Article in BMC medical research methodology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.4field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Giovanni BajDepartment of Mathematics and Geosciences, University of Trieste, Trieste, Italy. giovanni.baj@phd.units.it.
Ilaria GandinDepartment of Medical Sciences, Biostatistics Unit, University of Trieste, Trieste, Italy.
Arjuna ScagnettoCardiovascular Center, Territorial Specialistic Department, University Hospital and Health Services of Trieste, Trieste, Italy.
Luca BortolussiDepartment of Mathematics and Geosciences, University of Trieste, Trieste, Italy.
Chiara CappellettoCardiovascular Center, Territorial Specialistic Department, University Hospital and Health Services of Trieste, Trieste, Italy.
Andrea Di LenardaCardiovascular Center, Territorial Specialistic Department, University Hospital and Health Services of Trieste, Trieste, Italy.
Giulia BarbatiDepartment of Medical Sciences, Biostatistics Unit, University of Trieste, Trieste, Italy.
University of Trieste · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMachine learning (ML) methods to build prediction models starting from electrocardiogram (ECG) signals are an emerging research field. The aim of the present study is to investigate the performances of two ML approaches based on ECGs for the prediction of new-onset atrial fibrillation (AF), in terms of discrimination, calibration and sample size dependence.

methodsWe trained two models to predict new-onset AF: a convolutional neural network (CNN), that takes as input the raw ECG signals, and an eXtreme Gradient Boosting model (XGB), that uses the signal's extracted features. A penalized logistic regression model (LR) was used as a benchmark. Discrimination was evaluated with the area under the ROC curve, while calibration with the integrated calibration index. We investigated the dependence of models' performances on the sample size and on class imbalance corrections introduced with random under-sampling.

resultsCNN's discrimination was the most affected by the sample size, outperforming XGB and LR only around n = 10.000 observations. Calibration showed only a small dependence on the sample size for all the models considered. Balancing the training set with random undersampling did not improve discrimination in any of the models. Instead, the main effect of imbalance corrections was to worsen the models' calibration (for CNN, integrated calibration index from 0.014 [0.01, 0.018] to 0.17 [0.16, 0.19]). The sample size emerged as a fundamental point for developing the CNN model, especially in terms of discrimination (AUC = 0.75 [0.73, 0.77] when n = 10.000, AUC = 0.80 [0.79, 0.81] when n = 150.000). The effect of the sample size on the other two models was weaker. Imbalance corrections led to poorly calibrated models, for all the approaches considered, reducing the clinical utility of the models.

conclusionsOur results suggest that the choice of approach in the analysis of ECG should be based on the amount of data available, preferring more standard models for small datasets. Moreover, imbalance correction methods should be avoided when developing clinical prediction models, where calibration is crucial.

Indexed as

Atrial FibrillationBenchmarkingCalibrationElectrocardiographyHumansMachine LearningAtrial fibrillationCalibrationDeep learningMachine learningPrediction

Identifiers

PMID37481514
PMCPMC10363301
OpenAlexW4385145683

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.