Evidence map›Paper›PMID 37478080›Full record

ArticlePloS one2023

Improved Simultaneous Multi-slice imaging with Composition of k-space Interpolations (SMS-COOKIE) for myocardial T1 mapping.

Ömer Burak Demirel, Sebastian Weingärtner, Steen Moeller, Mehmet Akçakaya

Abstract read
In one paragraph

Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Simultaneous multislice cardiac multimapping based on locally low-rank and sparsity constraints.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2024
    Article
  2. Customizing native T1 mapping: The effects of compressed sensing, deep learning-based denoising, and high-resolution on measurement of native myocardial T1.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ömer Burak DemirelElectrical and Computer Engineering, University of Minnesota, Minneapolis, Minnesota, United States of America.ORCID 0000-0003-4726-0590
Sebastian WeingärtnerDepartment of Imaging Physics, Delft University of Technology, Delft, The Netherlands.ORCID 0000-0002-0739-6306
Steen MoellerCenter for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, United States of America.
Mehmet AkçakayaElectrical and Computer Engineering, University of Minnesota, Minneapolis, Minnesota, United States of America.

Funding

TRD4 - Ultrahigh Field Engineering and SafetyP41EB027061 · NIBIB · UNIVERSITY OF MINNESOTA · PI Gregory John Metzger, KAMIL UGURBIL · 2019 to 2026
$11.7M
Rapid Comprehensive Cardiac MRI Exam for Diagnosis of Coronary Artery DiseaseR01HL153146 · NHLBI · UNIVERSITY OF MINNESOTA · PI AKCAKAYA, MEHMET · 2020 to 2024
$2.5M
Novel Quantitative MRI Techniques for the Assessment of Cardiac Fibrosis without Gadolinium ContrastR21EB028369 · NIBIB · UNIVERSITY OF MINNESOTA · PI AKCAKAYA, MEHMET · 2020 to 2022
$602k
NHLBI NIH HHS R01 HL153146NIBIB NIH HHS P41 EB027061NIBIB NIH HHS R21 EB028369
6 · The paper itself

Abstract

The aim of this study is to develop and evaluate a regularized Simultaneous Multi-Slice (SMS) reconstruction method for improved Cardiac Magnetic Resonance Imaging (CMR). The proposed reconstruction method, SMS with COmpOsition of k-space IntErpolations (SMS-COOKIE) combines the advantages of Iterative Self-consistent Parallel Imaging Reconstruction (SPIRiT) and split slice-Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA), while allowing regularization for further noise reduction. The proposed SMS-COOKIE was implemented with and without regularization, and validated using a Saturation Pulse-Prepared Heart rate Independent inversion REcovery (SAPPHIRE) myocardial T1 mapping sequence. The performance of the proposed reconstruction method was compared to ReadOut (RO)-SENSE-GRAPPA and split slice-GRAPPA, on both retrospectively and prospectively three-fold SMS-accelerated data with an additional two-fold in-plane acceleration. All SMS reconstruction methods yielded similar T1 values compared to single band imaging. SMS-COOKIE showed lower spatial variability in myocardial T1 with significant improvement over RO-SENSE-GRAPPA and split slice-GRAPPA (P < 10-4). The proposed method with additional locally low rank (LLR) regularization reduced the spatial variability, again with significant improvement over RO-SENSE-GRAPPA and split slice-GRAPPA (P < 10-4). In conclusion, improved reconstruction quality was achieved with the proposed SMS-COOKIE, which also provided lower spatial variability with significant improvement over split slice-GRAPPA.

Indexed as

Image Processing, Computer-AssistedMagnetic Resonance ImagingAlgorithmsBrainHeartMyocardiumPhantoms, ImagingRetrospective Studies

Identifiers

PMID37478080
PMCPMC10361528

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.