ArticleInvestigative ophthalmology & visual science2023
Corneal Biomechanical Properties Demonstrate Anisotropy and Correlate With Axial Length in Myopic Eyes.
Article in Investigative ophthalmology & visual science, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Relationship Between Scheimpflug-Based Ocular Biomechanics and Myopic Maculopathy.Bioengineering (Basel, Switzerland) · 2026Article
- Transformative biomechanics and mechanobiology breakthroughs shaping the future of health and medicine.Innovation (Cambridge (Mass.)) · 2026Review
- Soft, Flexible, and Stretchable Platforms for Tissue-Interfaced Bioelectronics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Review
- Preoperative Corneal Astigmatic Direction is Associated with Stromal Mechanical Anisotropy in SMILE-Derived Lenticules.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
- Influence of axial length and myopia severity on the achieved optical zone in KLEx surgery: a pilot study.European journal of medical research · 2025Article
- A 10-year retrospective study on the prevalence and biometric characteristics of high myopia in Chinese cataract surgery candidates.Scientific reports · 2025Article
- Evaluation of the Long-Term Corneal Biomechanics Following SMILE With Different Residual Stromal Bed Thickness in Rabbits.Translational vision science & technology · 2025Article
- The correlation between intraocular pressure and choroidal microcirculation in patients with high myopia.International journal of medical sciences · 2025Observational
- Potential dynamic corneal response parameters for myopia: relationships between axial length with whole eye movement at the first and second applanations and the highest concavity.BMC ophthalmology · 2024Article
- Brillouin microscopy for focal biomechanical measurements in normal and keratoconic corneas: A narrative review.Survey of ophthalmologyReview
- Corneal Biomechanics as a Causal Factor in Myopia and Astigmatism: Evidence from Mendelian Randomization.Ophthalmology scienceArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: The purpose of this study was to investigate the ex vivo and in vivo biomechanical characteristic of cornea in myopic eyes. Methods: Fifty-one corneal stromal lenticules were obtained from myopic eyes during the SMILE procedure and were tested by a biaxial tensile system within 24 hours postoperatively. The material properties of the lenticules were described using stress-strain curves and were compared among axial length (AL) <26 mm and AL ≥ 26 mm group. Pre-operative stress-strain index (SSI) parameters were used to evaluate the biomechanical properties of the cornea in vivo. Results: Compared with AL < 26 mm, the tangent modulus significantly decreased in horizontal and vertical directions when AL ≥ 26 mm (P < 0.05); SSI also significantly decreased when AL ≥ 26 mm (P < 0.05). Anisotropic parameter is positively correlated with AL (r = 0.307, P < 0.05). Compared with AL < 26 mm, anisotropic parameter significantly increased when AL ≥ 26 mm (P < 0.05). SSI was negatively correlated with AL (r = -0.380, P < 0.05) in the AL < 26 mm group but not in the AL ≥ 26 mm group (P > 0.05). Compared with 26 mm ≤ AL < 27 mm group, the tangent modulus significantly decreased in the horizontal direction (P < 0.05) but not in the vertical direction when 27 mm ≤ AL < 28 mm (P > 0.05). Conclusions: The biomechanical properties of cornea decreased with the increase of AL. Tangent modulus significantly decreased in the horizontal direction compared with vertical direction. AL should be taken into account during calculation of corneal biomechanical parameters in order to improve validity.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.