A novel device with pedicular anchorage provides better biomechanical properties than balloon kyphoplasty for the treatment of vertebral compression fractures.

Jean-Charles Le Huec, Thomas Droulout, Lisa Boue, Edouard Dejour, Sonia Ramos-Pascual, Stephane Bourret

Open access · goldAbstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Jean-Charles Le HuecPolyclinique Bordeaux Nord Aquitaine, Vertebra Center, 33 Rue du Dr Finlay, 33300, Bordeaux, France.
Thomas DrouloutSafe Orthopaedics, Allée Rosa Luxemburg, 95610, Eragny Sur Oise, France.
Lisa BouePolyclinique Bordeaux Nord Aquitaine, Vertebra Center, 33 Rue du Dr Finlay, 33300, Bordeaux, France.
Edouard DejourReSurg SA, Rue Saint-Jean 22, 1260, Nyon, Switzerland.
Sonia Ramos-PascualReSurg SA, Rue Saint-Jean 22, 1260, Nyon, Switzerland. sonia@resurg.eu.ORCID http://orcid.org/0000-0002-0409-613X
Stephane BourretPolyclinique Bordeaux Nord Aquitaine, Vertebra Center, 33 Rue du Dr Finlay, 33300, Bordeaux, France.
Polyclinique Bordeaux Nord Aquitaine · FRFederal Roads Office · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare the biomechanical behavior of vertebrae with vertebral compression fractures (VCF) treated by a novel system with pedicular anchorage (dowelplasty) versus balloon kyphoplasty.

methodsFour cadaveric spines (T12-L5) were harvested, cleaned from soft tissues, and separated into vertebrae. Axial compressive loads were applied to each vertebra until a VCF was generated. Half of the vertebrae (n = 11) were instrumented using the "dowelplasty" system, consisting of a hollow titanium dowel anchored into the pedicle, through which a cannulated titanium nail is inserted and locked and through which cement is injected. The other half (n = 11) were instrumented using balloon kyphoplasty. Axial compressive loads were re-applied to each vertebra until fracture. Fracture load and fracture energy were calculated from load-displacement data for the pre- and post-treatment states.

resultsCompared to balloon kyphoplasty, dowelplasty granted greater net change in fracture load (373N; 95%CI,-331-1076N) and fracture energy (755Nmm; 95%CI,-563-2072Nmm). A sensitivity analysis was performed without L4 and L5 vertebrae from the dowelplasty group, since the length of the cannulated nails was too short for these vertebrae: compared to balloon kyphoplasty, dowelplasty granted an even greater net change in fracture load (680N; 95%CI,-96-1457N) and fracture energy (1274Nmm; 95%CI,-233-2781Nmm).

conclusionTreating VCFs with dowelplasty grants increased fracture load and fracture energy compared to the pre-treatment state. Furthermore, dowelplasty grants greater improvement in fracture load and fracture energy compared to balloon kyphoplasty, which suggests that dowelplasty may be a good alternative for the treatment of VCF. LEVEL OF EVIDENCE: level IV.

Indexed as

Balloon kyphoplastyBiomechanical studyFracture loadVertebral compression fracture, dowelplasty

Identifiers

PMID37477733
PMCPMC10361952
OpenAlexW4384924459

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.