Evidence map›Paper›PMID 37477682›Full record

ArticleInternational orthopaedics2023

Reverse traction with Kirschner wires and bilateral external fixation device combined with minimally invasive plate oseoynthesis technique for tibial plateau fractures of type Schatzker V and VI.

Wei-Qiang Zhao, Xu-Song Li, Jiang Hua, Jie-Feng Huang

Abstract read
PubMed Publisher
In one paragraph

Article in International orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. [Application of minimally invasive techniques in clinical treatment of tibial plateau fractures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2025
    Review
  3. [Application of intermediate screw assisted reduction and fixation technique in treatment of Schatzker typeZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2025
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Wei-Qiang Zhao *Department of Orthopaedics & Traumatology, The First Affiliated Hospital of Zhejiang Chinese Medical University, 54 Youdian Road, Shangcheng District, Hangzhou, 310006, Zhejiang, China.
Xu-Song Li *Department of Orthopaedics & Traumatology, Zhongshan Hospital of Traditional Chinese Medicine, Zhongshan, 528401, Guangdong, China.
Jiang HuaDepartment of Orthopaedics & Traumatology, The First Affiliated Hospital of Zhejiang Chinese Medical University, 54 Youdian Road, Shangcheng District, Hangzhou, 310006, Zhejiang, China. hjhjszyy@163.com.
Jie-Feng HuangDepartment of Orthopaedics & Traumatology, The First Affiliated Hospital of Zhejiang Chinese Medical University, 54 Youdian Road, Shangcheng District, Hangzhou, 310006, Zhejiang, China. 40983285@qq.com.ORCID http://orcid.org/0000-0002-1982-6641
Zhejiang Chinese Medical University · CNZhongshan Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeComplex bicondylar tibial plateau fracture (TPF) has always been a tricky problem for surgeons. We created a novel external device used intraoperatively consisting of Kirschner wires, and combined with minimally invasive plate oseoynthesis (MIPO) technique to treat complex bicondylar TPFs, and the clinical effect and feasibility were further evaluated.

methodsFrom March 2016 to February 2021, 49 cases (29 males and 20 females) were identified as bicondylar TPF, the mean age 47.2 (27-69). All patients adopted the device and MIPO technique. A series of score, complications, and radiographs in the follow-up period, from three months, six months, one year, and two years and the last follow-up, were recorded, from visual analogue score (VAS), hospital for special surgery (HSS), and Short-Form 36 (SF-36), containing physical (PCS) and mental (MCS), and Rasmussen score.

resultsForty-seven patients showed good functional recovery. No patients were lost, mean follow-up time was 28.17 ± 2.81 (24.2-35.4) months. Operation time was 89.80 ± 13.46 (58-110) min. At the last follow-up, VAS was 1.3 ± 0.92 (0-4), HHS was 93.10 ± 2.63 (89-99), PCS was 49.20 ± 7.40 (38-65), and MCS was 50.08 ± 4.77 (43-62). Complications were as follows: cutaneous necrosis (3, 6%), asymptomatic arthritis (3, 6%), symptomatic arthritis (1, 2%), and deep venous thrombosis (1, 2%). Mean fracture healing time was 11.82 ± 1.5 (10-15.4) weeks. All patients got recovery without extra surgery and removed the implants at 12.85 ± 0.76 (11.2-15.4) months.

conclusionTemporary traction device of bilateral external fixator combined with MIPO technique was simple and convenient, with a smaller soft-tissue damage, an easier operational approach, and its worth being promoted.

Indexed as

Tibial FracturesTibial Plateau FracturesBone PlatesBone WiresExternal FixatorsFemaleFracture FixationFracture Fixation, InternalHumansMaleMiddle AgedTractionTreatment OutcomeA novel deviceBicondylar tibial plateau fractureMinimally invasive plate osteosynthesisSchatzker V and VI

Identifiers

PMID37477682
OpenAlexW4384925328

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.